4-7g
4-4 RECEIVE ADJUSTMENTS
 
 
ADJUSTMENT ADJUSTMENT SETUP OPER ATION
ADJUSTMENT
ITEM/POINT
VALUE
RX TUNING
VOLTAGE
1 CH No.: [AM Low]
Receiving
Connect the digital voltmeter
to the CP5 on the MAIN unit.
[F17]
(Adjustment screen)
5.0 V (±0.1 V)
RX BPF (AM)
~Adjustment~
1 CH No.: [AM Low]
Receiving
Connect the digital voltmeter
to the CP10 on the MAIN
unit.
Connect the standard signal
generator (SSG) to the
antenna connector, and set
it to:
Frequency: 118.000 MHz
 

Modulation: 1 kHz
Deviation: 30%
L2, L4, L8, L10
(MAIN unit)
Minimum
voltage
2 CH No.: [AM Mid]
Receiving
Set the SSG to:
Frequency: 127.500 MHz
[F18]
(Adjustment screen)
3 CH No.: [AM High]
Receiving
Set the SSG to:
Frequency: 136.975 MHz
[F19]
(Adjustment screen)
~Verification~ 4 CH No.: [AM Low]
Receiving
Connect the distortion meter
to the external speaker line

Set the SSG to:
Frequency: 118.000 MHz
Level*:
To the level
so that the
distortion
meter shows
6 dB S/N or
12 dB SINAD.
For IC-A210/
IC-A220:
Less than

(6 dB S/N)
For IC-A210E:
Less than

(12 dB SINAD:
with CCIT filter)
5 CH No.: [AM Mid]
Receiving
Set the SSG to:
Frequency: 127.500 MHz
6 CH No.: [AM High]
Receiving
Set the SSG to:
Frequency: 136.975 MHz
For only IC-A210
and IC-A220:
RX BPF (FM)
~Preparation~
1 Set the preset value on the
adjustment screen.
[F21] 255
~Adjustment~ 2 CH No.: [FM Low]
Receiving
Connect the standard signal
generator (SSG) to the
antenna connector, and set
it to:
Frequency: 161.650 MHz
 

Modulation: 1 kHz
Deviation: 3.5 kHz
Connect the digital voltmeter
to the CP13 on the MAIN
unit.
[F20]
(Adjustment screen)
Maximum
voltage
3 CH No. : [FM High]
Receiving
Set the SSG to:
Frequency: 163.275 MHz
[F21]
(Adjustment screen)
~Verification~
4 CH No.: [FM Low]
Receiving
Connect the distortion meter
to the external speaker line
with the 4 load.
Set the SSG to:
Frequency: 161.650 MHz
More than
12 dB SINAD
5 CH No. : [FM High]
Receiving
Set the SSG to:
Frequency: 163.275 MHz
(Replacement page)
July 2019
The underlined parts have been updated from the previous version of the addendum, or the original page.
Continued on the next page…
For only IC-A220.
*The output level of the standard signal generator (SSG) is indicated at the load end (PD).