28
STESkW ed 05/06 EOLO Star 23 kW
Technical DocumentationTechnical Documentation
Technical data.
EOLO Star 23 kW technical data.
- e flue temperature values refer to an air inlet temperature
of 15°C.
- D
ata relative to d.h.w. performance refer to a dynamic inlet
pressure of 2 bar and an inlet temperature of 15°C; these
values are measured at boiler outlet considering that to find
these declared values mixing with cold water is necessary.
Rated heating power
Min. heating power
Rated heat output (useful)
Min. heat output (useful)
Useful thermal efficiency at rated output
Useful thermal efficiency at 30% rated output
Heat loss at shell with burner On/Off
Heat loss at flue with burner On/Off
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
25,1 (21586)
7,9 (6834)
23,8 (20485)
7,0 (6000)
94,9
91,1
0,4 / 0,54
4,7 / 0,02
G20 G30 G31
Gas nozzle diameter
S
upply pressure
mm
mbar (mm H
2
O)
1,25
20 (204)
0,76
29 (296)
0,76
37 (377)
Max. working pressure heating circuit
Max. working temperature heating circuit
Adjustable heating temperature
Total volume heating expansion tank
Heating expansion tank precharge
Generator water capacity
Head available with flowrate 1000/h
Hot water production available heat output
Domestic hot water adjustable temperature
Domestic circuit flow limiter
Flow limiter rated delivery min. pressure
Domestic circuit min. pressure (dynamic)
Domestic circuit max. working pressure
Min. drawing domestic hot water
Drawing capacity in continuous duty (∆T 30°C)
Specific capacity (∆T 30°C)
Weight of boiler full
W
eight of boiler empty
bar
°C
°C
l
bar
l
kPa (m H
2
O)
kW (kcal/h)
°C
l/min
bar
bar
bar
l/min
l/min
l/min
kg
kg
3
90
35 - 80
3,95
1,0
3,5
25,5 (2,6)
23,8 (20485)
35 - 55
8
1,0
0,3
10
1,5
11,1
10,7
38
34
Electrical connection
Rated absorption
Installed electrical po
wer
Power absorbed by circulating pump
Power absorbed by fan
Appliance electrical system protection
V/Hz
A
W
W
W
-
230/50
0,79
135
73
43
IPX4D
G20 G30 G31
Mass flo
w of fumes at rated power
Mass flow of fumes at min. power
CO
2
at Q. Rated/Min.
CO with 0% O
2
at Q. Rated/Min.
NOX with 0% O2 at Q. Rated/Min.
Temperature of fumes at rated power
Temperature of fumes at min. power
kg/h
kg/h
%
ppm
ppm
°C
°C
52
51
6,9 / 2,1
53 / 53
62 / 17
107
83
52
42
8,0 / 3,0
79 / 66
80 / 20
105
86
54
44
7,7 / 2,8
28 / 15
75 / 20
109
83
NO
X
class
NO
X
weighted
CO weighted
-
mg/kWh
mg/kWh
3
106
89
Type of appliance C12 /C32 / C42 / C52 / C82 / B22 / B32
Categor
y II2H3+
http://serviceimmergas.ro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas EOLO Star 23 kW and is the answer not in the manual?

Immergas EOLO Star 23 kW Specifications

General IconGeneral
Output Power23 kW
Efficiency93.5%
Weight32 kg
MountingWall-mounted
Max Operating Temperature85°C
IgnitionElectronic
Heat Exchanger MaterialStainless Steel
Fuel TypeNatural gas
Water Pressure0.3 - 6 bar