Appendix B: Integrated BMC Sensor Tables Intel® Server Board S1200BT TPS
Revision 1.0
Intel order number G13326-003
122
Table 56. BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading Type
Event Offset Triggers
Contrib. To System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-by
Power Unit Status
(Pwr Unit Status)
01h
All
Power Unit
09h
Sensor Specific
6Fh
00 - Power down
OK
As and
De
Trig
Offset
A
X
04 - A/C lost
05 - Soft power control
failure
Fatal
06 - Power unit failure
Power Unit
Redundancy1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As and
De
Trig
Offset
A
X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 Redundant:
degraded from fully
redundant state.
Degraded
07 Redundant:
Transition from non-
redundant state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h
All
Watchdog 2
23h
Sensor Specific
6Fh
00 - Timer expired,
status only
OK
As
Trig
Offset
A
X
01 - Hard reset

Table of Contents