Output Commands
Copyright© Itech Electronics Co., Ltd. 32
Command Arguments
ON|OFF|1|0
Example
CURR:PROT:STAT 1
Reset Value
1
Query syntax
[SOURce:]CURRent:PROTection:STATe?
Returns
0|1
[SOURce:]CURRent:PROTection[:LEVel]
This command is used to set current value for over current protection.
Command syntax
[SOURce:]CURRent:PROTection[:LEVel] <MINimum|MAXimum|DEFault|NRf>
Arguments
MINimum|MAXimum|DEFault|NRf
Unit
A
Reset Value
MAXimum
Example
CURR:PROT 10.0
Query syntax
[SOURce:]CURRent:PROTection[:LEVel]? [MINimum|MAXimum|DEFault]
Returns
NRf
[SOURce:]CURRent:PROTection:DELay
This command is used to set delay time for over current protection.
Command syntax
[SOURce:]CURRent:PROTection:DELay <MINimum|MAXimum|NRf>