EasyManuals Logo
Home>ITech>Power Supply>IT6500C Series

ITech IT6500C Series Manual

ITech IT6500C Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Load Related CommandIT6500C
Copyright© Itech Electronics Co., Ltd. 56
Unit
W
Reset Value
MAXimum
Example
LOAD:POW MIN
Query syntax
LOAD:POWer[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf
LOAD:POWer:MINimum[:LEVel]
This command is used to set minimum power of load.
Command syntax
LOAD:POWer:MINimum[:LEVel] [MINimum|MAXimum|NRf]
Arguments
MINimum|MAXimum|NRf
Unit
W
Reset Value
0.0
Example
LOAD:POW:MIN 2.0
Query syntax
LOAD:POWer:MINimum[:LEVel]? [MINimum|MAXimum]
Returns
NRf
Related Command
LOAD:POW:MAX,LOAD:POW
LOAD: POWer:MAXimum[:LEVel]
This command is used to set maximum value of power.

Table of Contents

Other manuals for ITech IT6500C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6500C Series and is the answer not in the manual?

ITech IT6500C Series Specifications

General IconGeneral
BrandITech
ModelIT6500C Series
CategoryPower Supply
LanguageEnglish

Related product manuals