Communication protocol
Copyright © Itech Electronic Co., Ltd. 6
Byte 0 of the maximum voltage value
Byte 1 of the maximum voltage value
Byte 2 of the maximum voltage value
Byte 3 of the maximum voltage value
Byte 0 of output voltage value
Byte 1 of output voltage value
Byte 2 of output voltage value
Byte 3 of output voltage value
Note
We use 1 byte to represent power supply’s state. Each bit is defined as follows:
From higher bit to lower bit:
7 6 5 4 3 2 1 0
0 bit: The output state, 0 is OFF, 1 is ON.
1 bit: Over heat protection, 0 is normal, 1 is abnormal.
2, 3 bit: The output mode, 1 is CV mode, 2 is CC mode and 3 is Unreg mode.
4, 5, 6 bit: The fan speed, 0 is stop, 5 is the maximum fan speed.
7 bit: Operation state, 0 is front panel operation mode, 1 is remote control mode.
The frame format is the same as above
3.8 Entering the Calibration Mode (27H)
Calibration protection state
Calibration password (0X28H)
Calibration password (0X01H)
Note
We use a byte to represent calibration protection state, each bit is defined as follows:
From higher bit to lower bit:
7 6 5 4 3 2 1 0
0 bit: Protection state, 0 is to disable protection, 1 is to enable the protection.
3.9 Reading the Calibration State (28H)
Calibration protection state
Note
We use a byte to represent calibration protection state, each bit is defined as follows:
From higher bit to lower bit:
7 6 5 4 3 2 1 0