EasyManuals Logo
Home>ITech>Power Supply>IT6821

ITech IT6821 Programming Guide

ITech IT6821
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Communication protocol
Copyright © Itech Electronic Co., Ltd. 7
0 bit: Protection state, 0 is to disable protection, 1 is to enable the protection.
3.10 Calibrating the Voltage Value (29H)
1
st
byte
Start bit (AAH)
2
nd
byte
Address (0 to 0XFE)
3
rd
byte
Command (29H)
4
th
byte
Calibrated voltage points (point 1 to 3)
5
th
to 25
th
byte
System reserve
26
th
byte
Check sum
Note
To calibrate the 3 points of voltage sequentially.
3.11 Sending the Present Output Voltage to Calibration
Program (2AH)
1
st
byte
Start bit (AAH)
2
nd
byte
Address (0 to 0XFE)
3
rd
byte
Command (2AH)
4
th
byte
The byte 0 of present voltage value
5
th
byte
The byte 1 of present voltage value
6
th
byte
The byte 2 of present voltage value
7
th
byte
The byte 3 of present voltage value
8
th
to 25
th
byte
System reserve
26
th
byte
Check sum
3.12 Calibrate the Current Value (2BH)
1
st
byte
Start bit (AAH)
2
nd
byte
Address (0 to 0XFE)
3
rd
byte
Command (2BH)
4
th
byte
Calibrated current points (point 1 to 2)
5
th
to 25
th
byte
System reserve
26
th
byte
Check sum
Note
To calibrate the 2 points of the current value sequentially.
3.13 Sending the Actual Output Current to Calibration
Program (2CH)
1
st
byte
Start bit (AAH)
2
nd
byte
Address (0 to 0XFE)
3
rd
byte
Command (2CH)
4
th
byte
The lower byte of the present current value
5
th
byte
The higher byte of the present current value
6
th
to 25
th
byte
System reserve
26
th
byte
Check sum

Other manuals for ITech IT6821

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6821 and is the answer not in the manual?

ITech IT6821 Specifications

General IconGeneral
BrandITech
ModelIT6821
CategoryPower Supply
LanguageEnglish

Related product manuals