Communication protocol
Copyright © Itech Electronic Co., Ltd. 9
3.18 Restore the Factory Default Calibration Data (32H)
3.19 Enable the Local Key (37H)
Enable/disable local key (0 is disable, 1 is enable)
Note
The local keys on the front panel are not allowed to use when the power supply is in
remote mode.
3.20 The Return Information of Command Operation in
Power Supply (12H)
Note
When the power supply receives a frame command, it will check the frame command.
If the check sum is correct, then it will return the corresponding reading parameters.
If the check sum is incorrect, then it will return to 90H.
If there is any error on setting parameter or over parameter, then it will return to A0H.
If the command wasn’t executed, then it will return to B0H.
If the command is not effective, then it will return to C0H.
Or otherwise, it will return to 80H.