Copyright ©ITECH Electronic Co., Ltd. 16
STATus:QUEStionable:ENABle <enabled value>
This order can set the parameter of quest event enable register. The power
supply will return a decimal number which is the
binary-weighted sum of the
enable register.
Order syntax:
STATus:QUEStionable:ENABle <NRf>
Parameter:
0 to 65535
Reset value:
Consult *PSC order
Example:
STATus:QUEStionable:ENABle 16
Quest syntax:
STATus:QUEStionable:ENABle?
Return parameter:
<NR1>
Reference order:
*PSC
SYSTem:VERSion?
This order can query the version of the SCPI order. Returned value is a string
like “YYYY.V”, In which the YYYY is the year of this version, V is the version.
Order syntax:
SYST:VERS?
Parameter:
None
Return parameter:
<NR2>
Example:
1.00, 1991.1