EasyManuals Logo
Home>ITech>Power Supply>IT6942A

ITech IT6942A Programming Guide

ITech IT6942A
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Voltage Control Commands
Copyright ©ITECH Electronic Co., Ltd. 31
Return parameters:
<NR2>
VOLT:PROTection {<volts>|MINimum|MAXimum}
This order is used to set the upper limit of over voltage protection point. If the
output voltage value is higher than the upper limit of OVP, then we can assume
that internal parts has been shorted. Query state register ”OV” bit has been set.
When power supply is protected, then we can through order VOLT:PROT:CLE
to clear the OVP state.
Order syntax:
[SOURce:]VOLTage:PROTection[:LEVel] <NRf>
Parameters:
MIN to MAX
Unit:
V
Query syntax:
VOLT:PROT? { MINimum|MAXimum}
Return parameters:
<NR2>
VOLT:PROTection:STATe {0|1|OFF|ON}
This order is used to open or close OVP function i.e. to set the state of OVP.
Order syntax:
[SOURce:]VOLTage:PROTection:STATe
Parameters:
0|1|OFF|ON
Query syntax:
VOLTage:PROTection:STATe?
Return parameters:
0|1
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT6942A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6942A and is the answer not in the manual?

ITech IT6942A Specifications

General IconGeneral
BrandITech
ModelIT6942A
CategoryPower Supply
LanguageEnglish

Related product manuals