10.6 Timers
Timers are used by the control unit to count down the
different time dependent functions such as Extra hot
water duration. At customer level the following timers
can be observed (only timers that are counting are
displayed):
10.7 External controls
When an external input is connected, the control unit
performs functions which are set to Yes or is separated
from 0 (Room temperature). When the external input is
no longer connected, the control unit returns to normal
mode. Only installed functions are displayed.
> External input 1, 2
>> Block compressor
>> Block heating
>> Room temperature
>> Block hot water production
> External input circuit 2, 3...(optional)
>> Block heating
>> Room temperature
Room temperature:
B Set the room temperature that should apply in the
event of enabled external control.
B Value > 0 °C enables the function.
Other functions:
10.8 General
Among other things, settings for date and time are
available here.
> Set date
> Set time
B Check and change, if necessary, date and time. These
are used by the control unit to manage the different
clock settings, e.g., holiday and room temperature
program.
> Summer/winter time
B Select if there should be automatic change over
between summer and winter time or not (times
according to EU standard).
> Display backlight intensity
B If necessary, change the background light of the
control panel.
> Language
B Change language, if desired.
Timer F value
Extra hot water 0h
Alarm mode delay 1h
Party 0h
Operating time for heating at hot water
demand
20min
Hot water, operating time at heating
demand
30min
Heat pump x timers
> Compressor start delay 10min
Additional heat timers
> Additional heat start delay 60min
> Delay mixing valve control after
additional heat start
20min
Tab. 34 Timers
Factory setting No (0.0 °C)
Lowest value 10.0 °C
Highest value 35.0 °C
Tab. 35 Room temperature
F value No
Alternative Yes/No
Tab. 36 Functions
Factory setting
Format yyyy-mm-dd
Tab. 37 Date
Factory setting
Format hh:mm:ss
Tab. 38 Time
Factory setting Automatic
Alternative Manual/Automatic
Tab. 39 Summer/winter time.
Factory setting 100%
Lowest value 20%
Highest value 100%
Tab. 40 Display backlight intensity