J-100
6.0 Power Requirements
Jacuzzi spas are designed to provide optimum performance and
exibility of use when connected to the maximum electrical service listed
below. Minor circuit board modications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note: Refer to pages 36-37 for circuit board conguration details or
contact your authorized Jacuzzi dealer.
All North American J-135/J-145 Models (60 Hz)
240V/40A* 240V/50A** 240V/60A***
Circuit Breaker (2-Pole): 40A* 50A** 60A***
Number of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
*
In 40A conguration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
**
In 50A conguration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
***
In 60A conguration the heater will operate while both jets pumps
are running in high speed.
Export J-135/J-145 Models (50 Hz)
230V/20A* 230V/30A** 230V/40A***
Circuit Breaker: 20A* 30A** 40A***
Number of Wires: 3 3 3
Frequency: 50 Hz 50 Hz 50 Hz
Current Draw: 15A 23A 29A
*
In 20A conguration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
**
In 30A conguration, the heater will operate while one jets pump
is running in high speed. Note: pump 2 runs only in high speed.
***
In 40A conguration the heater will operate while both jets pumps
are running in high speed.
12