30
J-300
11.5 Selecting the Circulation Pump Filtration Cycle
Press and hold the Jets pump 1 ( ) and Cooler ( ) button
at the same time for 3 seconds to access the circulation pump
programming. Continually press the Warmer ( ) button to scroll up
through the cycles below. Then select a cycle and press the Jets pump
1 ( ) button to activate that cycle. Upon pressing the jets pump 1
button the system will save your selection, exit the program menu and
return to the main menu.
Note: After 10 seconds the programming screen will revert back to the
temperature if no buttons are pressed. You cannot have more than one
circulation pump cycle activated at a time.
0 hours of circulation per day
4 hours of circulation per day
8 hours of circulation per day (recommended factory
default setting for J335-J375 models)
12 hours of circulation per day
16 hours of circulation per day
20 hours of circulation per day
24 hours of circulation per day (recommended
factory default setting for J315 and J325 models)
For J335 to J375 models:
To set a time for the rst ltration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
rst ltration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM. Start time is approximate and may
vary slightly from day to day.
Note: If the circulation pump ltration cycle is interrupted or turned off;
the duration of the cycle will not be extended once spa functions resume.
Example: If the spa is set to cycle for 8 hours and only runs for 2 hours
before the interruption, once functions resume it will not continue to cycle
for another 6 hours, if the 8-hour cycle time has expired.
For J315 and J325 models:
The recommended factory default setting is 24 hours. This setting
should not be altered. Running the circulation pump less than the factory
recommended time will result in issues with water quality maintenance.