J-300
14.7 Panel Flashes FL1 or FL2
A ashing “FL1” display means the ow switch is
malfunctioning open, the lter cartridge is excessively dirty or
an “air lock” condition has occurred at the circulation pump
intake. A ashing “FL2” display means the ow switch is
malfunctioning closed. In either case, the spa heater will deactivate and
jets pump #1 may also deactivate. To correct condition perform the
following:
1. Verify water level is above all jets but below lowest pillow. Add water
if necessary.
2. Check for clogged or dirty lter cartridge (Sec. 12.1, page 33).
3. Purge “air lock” from circulation pump intake by removing lter
cartridge. Hold your garden hose over the lter cartridge wall tting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall lter cartridge and
check spa (Sec. 12.1, page 33).
4. If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5. If problem persists, contact your authorized Jacuzzi dealer.
14.8 Panel Displays OH
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
Water temperature is above acceptable limits. DO NOT
ENTER SPA! Water temperature has reached 112°F (44°C)
and the low speed jets pump 1 and optional circulation pump
(when equipped) has activated to circulate water through heater. Contact
your authorized Jacuzzi dealer or qualied service technician.
To correct condition:
Remove the spa's cover and allow your spa to cool down.
Program the lter settings for Economy Mode (page 28). Raise
water temperature setting to cancel Summer Logic condition (page
45).
If the condition persists, contact your authorized Jacuzzi dealer.
14.9 Panel Displays (- - -)
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
Water temperature is above acceptable limits. DO NOT
ENTER SPA! The safety “Watchdog” software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its components.
Contact your authorized Jacuzzi dealer or qualified service technician.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J - 355 and is the answer not in the manual?

Jacuzzi J - 355 Specifications

General IconGeneral
BrandJacuzzi
ModelJ - 355
CategoryHot Tub
LanguageEnglish

Related product manuals