4. INSTALLING THE THREAD STAND
➊
Assemble the thread stand, set it up on the machine table
using the installation hole in the table and tighten nut
➊
gently.
– 14 –
5. LUBRICATION
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the follow-
ing work after turning the power off and ascertaining that the motor is at rest.
A
B
Lubricating procedure for the face plate portion
1) Loosen and remove screw
A
.
2) Open the face plate in the direction of arrow mark
B
.
3) Apply an adequate amount of oil once a day to the
points marked with the arrow marks.
4) Close the face plate.
5) Tighten and attach screw
A
.
– 15 –