English 5
GROUNDING
INSTRUCTIONS
This device must be grounded. If it
should malfunction or break down,
grounding provides a path of least
resistance for electric current to re-
duce the risk of electric shock.
This device is equipped with a cord
having an equipment grounding
conductor and ground plug.
The plug must be inserted into
an
appropriate outlet that is properly in-
stalled and grounded in accordance
with all local codes and ordinances.
WARNING:
Improper connection of the equip-
ment grounding conductor can re-
sult in a risk of electric shock.
Check with a qualified electrician or
service person if you are in doubt as
to whether the outlet is proper
ly
grounded.
Do not modify the plug provided with
the appliance.
If it will not fit the outlet, have a prop-
er outlet installed by a qualified elec-
trician.
This appliance is for use on a nomi-
nal 120-volt circuit, and ha
s a
grounded plug that looks like the
plug illustrated in Fig.A.
Make sure that the appliance is con-
nected to an outlet having the same
configuration as the plug. No adap-
tor should be used with this appli-
ance.
DO NOT ATTEMPT TO REPAIR
POWER CORD.
IN ALL CASES, MAKE SURE THE
RECEPTACLE IN QUESTION IS
PROPERLY GROUNDED.
NEVER REMOVE GROUNDING
PRONG FROM POWER PLUG.
EXTENSION CORDS
If an extension cord is absolutely nec-
essary, an extension cord rated a min-
imum of 15 ampere 14 gauge cord
should be used. Cords rated for less
amperage may overheat. Care should
be taken to arrange the cord so it can-
not be pulled or tripped over.
Figure A
1 Grounded outlet box
2 Current carrying prongs
Grounding prong is longest of the 3
prongs.
Safety devices
CAUTION
Missing or modified safety devices
Safety devices are provided for your
own protection.
Never modify or bypass safety devices.
Safety valve
In the case of excessively high pres-
sure in the event of a fault, a safety
valve relieves the pressure into the at-
mosphere.
Fuse
The fuse prevents the device from
overheating. If the device overheats,
the fuse disconnects the device from
the power supply.
Before restarting the device, contact
the KÄRCHER Customer Service at
1-800-537-4129.

Other manuals for Kärcher SC 3 Upright EasyFix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kärcher SC 3 Upright EasyFix and is the answer not in the manual?

Kärcher SC 3 Upright EasyFix Specifications

General IconGeneral
TypeSteam mop
Capacity0.5 L
Control typeButtons
Product colorBlack, Grey, Yellow
International Protection (IP) codeIPX4
AC input voltage220 - 240 V
AC input frequency50 - 60 Hz
Ready time0.5 min
Steam pressure- bar
Adjustable steamYes
Continuous steam performance40 g/min
Cable length5 m
Steam-ready light-
Weight and Dimensions IconWeight and Dimensions
Depth314 mm
Width207 mm
Height1185 mm
Weight3100 g