7
BASIC SAFETY INSTRUCTIONS
1.2.1 Residual risks
Despite intended use, the drive converter can reach unexpected operating conditions
in case of error, with wrong parameterization, by faulty connection or non-professional
interventions and repairs. This can be:
• wrong direction of rotation
• motor speed too high
• motor is running into limitation
• motor can be under voltage even in standstill
• automatic start
1.2.2 Unintended use
The operation of other electric consumers is prohibited and can lead to the destruction of
the unit. The operation of our products outside the indicated limit values of the technical
data leads to the loss of any liability claims.
If the KEB COMBIVERT F5 is used in machines, which work under exceptional condi-
tions or if essential functions, life-supporting measures or an extraordinary safety step
mustbefullled,thenecessaryreliabilityandsecuritymustbeensuredbythemachine
builder.
1.3 Transport, storage and proper use
Thetransportiscarriedoutbyqualiedpersonsinaccordancewiththeenvironmental
conditionsspeciedinthismanual.Driveconvertershallbeprotectedagainstexcessive
strains.
Transport of drive converters with an edge length >75 cm
The transport by forklift without suitable tools can cause a deflection of the heat
sink. This leads to premature aging or destruction of internal components.
► Transport of drive converters on suitable pallets.
► Do not stack drive converters or burden them with other heavy objects.
Drive converters contain electrostatic sensitive components.
► Avoid contact.
► Wear ESD-protective clothing.
Do not store drive converters
• in the environment of aggressive and/or conductive liquids or gases.
• with direct sunlight.
• outsidethespeciedenvironmentalconditions.