EasyManuals Logo
Home>Keithley>Measuring Instruments>SourceMeter 2400

Keithley SourceMeter 2400 Quick Start Guide

Keithley SourceMeter 2400
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
1-4 Return to Section Topics 2400S-903-01 Rev. E / September 2011
Section 1: Introduction Series 2400 SourceMeter® Quick Start Guide
Figure 1-2
Rear Panel
Navigating menus and entering numeric data
Menu navigation
Many operating modes for the SourceMeter are configured using front panel menus. Throughout
this guide, menu navigation will be presented as a sequence of key presses and menu item
selections. For example, the following sequence selects the auto ohms source mode:
Press CONFIG > press MEAS Ω > select SOURCE > select AUTO
The above sequence is explained as follows:
1. Press the CONFIG key.
2. Press the MEAS Ω key
.
3. Select the SOURCE menu item.
4. Select the AUTO ohms source mode.
A menu item is selected by placing the cursor
o
n it and pressing the ENTER key.
The left and right arrow keys control cursor position.
Numeric data entry (EDIT keys)
Numeric values must to be entered for some menu items. Numeric entry is also used to set source
and compliance values. The edit keys for numeric entry include the EDIT arrow keys to control
cursor position, EDIT arrow keys to increment or decrement the digit value, and the number keys.
After a value is keyed in, press ENTER to select it. Note that pressing MENU resets a displayed
number to its minimum value.
Editing source and compliance values
Editing keys
Use the following keys to edit source and compliance values:
WARNING: NO INTERNAL OPERATOR SERVICABLE PARTS, SERVICE BY QUALIFIED PERSONNEL ONLY.
CAUTION: FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE FUSE WITH SAME TYPE AND RATING.
MADE IN
U.S.A.
INPUT/
OUTPUT
250V
PEAK
250V
PEAK
TRIGGER
LINK
4-WIRE
SENSE
HI
LO
LINE RATING
100-240VAC
50, 60, Hz
190VA MAX.
RS-232
IEEE-488
(ENTER IEEE ADDRESS
WITH FRONT PANEL MENU)
250V
PEAK
5V
PEAK
5V
PEAK
5V
PK
V, Ω,
GUARD
GUARD
SENSE
LINE FUSE
SLOWBLOW
2.5A, 250V
OUTPUT
ENABLE
FUSE DRAWER
L
U
CUS
LISTED
SourceMeter
4ZA4
CAT I
!

Other manuals for Keithley SourceMeter 2400