EasyManuals Logo
Home>Key Automation>Gate Opener>SOLE

Key Automation SOLE User Manual

Key Automation SOLE
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
EN
Consumption chart
2.7 - Installation example
B
W
A
ITEM STATUS FUNCTION A/h W
CT10224 in stand-by no accesories SBY=1 0,0350 0,83
CT20224 in stand-by no accesories SBY=1 0,0270 0,65
MA24 with one PO24(gate closed)* in stand-by no accesories ENERGY SAVING=1 0,0195 0,47
in stand-by no accesories with RX4X/RX4Y ENERGY SAVING=1 0,0235 0,56
MA24 with two PO24(gate closed)* in stand-by no accesories ENERGY SAVING=1 0,0210 0,51
in stand-by no accesories with RX4X/RX4Y ENERGY SAVING=1 0,0250 0,6
FT32/22 One TX and one RX during activation in function 0,0290 0,69
ECLIPSE COURTESY light on in function 0,0325 0,77
FLASHLIGHT on in function 0,0200 0,99
LED strip (18 leds) in function 0,0325 0,77
* For MA24 no DYL (display) connected
Example of installation with SUN11024 and with 12 hours
Night Light System (NLS) (Eclipse + cover LED strip) and
without Night Light System.
ATTENTION !
DATA VALUE/DESCRIPTION
Location Venice, Italy
Sliding gate length 5mt
Gate weight 1000kg
Moving time 1 minute
Pause time 30 seconds
Nc (Cycles/day) 48
Daily NLS activated 12 hours (LIGHT INTENSITY default= 3)
Battery capacity 18Ah
Daily consumption= A+B+W+NLS
KEY AUTOMATION control units allow to read actual current draw
of motors during work cycle, see relative instruction.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation SOLE and is the answer not in the manual?

Key Automation SOLE Specifications

General IconGeneral
BrandKey Automation
ModelSOLE
CategoryGate Opener
LanguageEnglish

Related product manuals