EN
12 12
STARTUP INTERFACE
BATTERY VOLTAGE
BATTERY VOLTAGE BATTERY TYPE BATTERY TYPE RECOGNITION COMMUNICATION CODE
TEMPERATURE
ERROR CODE
AH-BATTERY
DISCHARGE METER
AH-BATTERY
CHARGE METER
INPUT CURRENT OUTPUT CURRENT
SYSTEM VOLTAGE RATED CURRENT SOFTWARE VERSION
Startup interface: the interface when system is powered on by
which you check whether the LCD is in good condition
System voltage: battery voltage detected by controller.
Rated current: Rated charging and discharging current of controller
Interface one-way circulation is performed by pressing
If there’s no failure, display presents the current interface until
press any key; if there ’s failure, after 20s absence of key operation
the error code interface is presented.
In interface "Battery voltage", or "Error code" by short pressing
load is switched on or o󰀨.
5.2 - LCD Interfaces
5.3 - Battery communication
Set System voltage to 24V
In interface "Ah-Battery Charge Meter" or "Ah-Battery Discharge
Meter" by long pressing (>3S) , data is cleared.
In "Battery voltage" interface, by long pressing , and
simultaneously until the screen is fully bright controller is restored
to factory defaults.
1. LVR, ABSORB , LVD , FLOAT , P(PM)
2. Day and night
3. Battery type: FLD , GEL , SLD , Null means Usr
4. Charging
5.Error
6. Discharging
7. Time
8. Capacity
9. Load state
10. Unit
11. Data display area
12. Button
5.1 - Symbols
5 - OPERATING INSTRUCTION
ATTENTION !

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation SOLE and is the answer not in the manual?