(1) DPF Regeneration Switch
(A) Activation (B) Deactivation
TE1O4A8A
DPF REGENERATION SWITCH
[CRDI]
ACTIVATION (UPPER BUTTON)
Perform the following procedure
when the regeneration warning lamp
comes on :
1. Park the vehicle on level ground
2. Start the engine and run the en-
gine at the idle speed.
3. Depress the brake pedal and lock
it in place.
4. Do not depress the clutch pedal.(if
equipped)
5. Put the range shift lever on the
neutral position
6. Run the engine 3 to 4 minutes.
Then, press the regeneration button
over 2 second.
DEACTIVATION (LOWER BUTTON)
Do not press the deactivation button
during the regeneration process.
However, in an emergency, press
the deactivation button to stop the
regeneration process.
This switch is used to switch the
PTO between automatic and manual
operation.
1. PTO Automatic
When the PTO selection switch
is put to the automatic operation
position, the PTO is automatically
disengaged after the hydraulic lift-
PTO AUTO/MANUAL SELECTION
SWITCH, PTO ON/OFF SWITCH
(1) PTO Auto / Manual Selection Switch
(2) PTO ON/OFF Switch (A) Automatic
(B) Manual (C) O
N (D) OFF
TE1O413B
[CABIN]
NOTE
The regeneration underway
lamp is turned on when the DPF
temperature reaches a certain
temperature.
•
7. The regeneration underway lamp
blinks after the regeneration warn-
ing lamp goes off.
Wait for approx. 30 to 40 minutes
until the regeneration process is
completed.