3. Maintenance
3.1 Maintenance schedule
Regular service period(1)
Item perform at every indicated
month or operating hour interval,
whichever comes first
Each use
First
month or
20 Hrs.
Every 3
months or
50Hrs.
Every 6
months or
100 Hrs.
Every
year or
300 Hrs.
Check
Engine Oil
Replace
Check
Air filter
Clean ●②
Spark plug Clean-Adjust
Spark catcher Clean-Adjust
Valve clearance Check-Adjust ●③
Fuel tank and filter Clean ●③
Fuel line Check Every 2 year (Replace if necessary)
Note:
(1) For commercial use, operation hours are determined by proper maintenance.
(2) Service more frequently when operating in dusty areas, every 10 hrs or every day.
(3) Service by KIPOR authorized agency, unless correct tools or professional specialist is available.
Do service according to the manual.
3.2 Engine oil
Checking for the oil level
Stop the engine and check the oil level, be sure to put the engine on a flat floor when checking.
1. Loosen the screws of the maintenance cover and remove the cover.
2. Remove the oil filler cap and check for the oil level.