EasyManuals Logo
Home>Kipor>Portable Generator>CG2000

Kipor CG2000 User Manual

Kipor CG2000
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
4. Tighten the crankcase cover bolt slowly, screw to the prescribed torque.
5. Wait for 20 minutes after installation, never refill in oil or start the engine during these 20 minutes.
11.6 Inspection
Inspection of oil alarm
(1) Stand the oil alarm, check the oil alarm output wire and copper earth wire, there should be no
continuity.
(2) Bottom up the oil alarm; check again, there should be continuity.
(3) Bottom up the oil alarm completely in the oil, check the float, there should be no continuity.
Cam height
Standard(mm) Service limit(mm)
29.026-29.086 28.15
58

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor CG2000 and is the answer not in the manual?

Kipor CG2000 Specifications

General IconGeneral
BrandKipor
ModelCG2000
CategoryPortable Generator
LanguageEnglish

Related product manuals