WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Determine Cabinet Opening
NOTE: Twist on wire connector. Gently tug on wires to be
sure both are secured.
Connect wires black to black and white to white, using UL
Listed/CSA Approved twist-on wire connectors (included
with power supply cord kit).
Remove the green grounding screw and place
through the ring terminal of the green ground wire.
Reattach and tighten the green screw.
Tighten strain relief screws to secure cord.
Place wires inside terminal box. Insert tabs
on left side of cover. Make sure wires are tucked inside
box. Close cover ensuring wires are not pinched. Use ¹⁄₄"
nut driver and previously removed screw to secure
cover.
NOTE: Do not plug into outlet until instructed to do so.
Measure height of cabinet opening from underside of
countertop to floor where dishwasher will be installed
(you will need to measure the lowest point on the
underside of the countertop and the highest point on the
floor). Refer to “Dishwasher Height Adjustment Chart”
for wheel position and the number of turns needed.