TP-7044 6/23 25
2.10.2 Engine Metering Submenu
Note:
Not all of these engine metering submenus may apply.
Engine Speed (Tachometer) displays the engine speed (RPM) at which the engine is presently running.
Oil Pressure displays the engine oil pressure.
Coolant Temperature displays the engine coolant temperature.
Fuel Rate displays the calculated fuel consumption rate based on fuel injector outputs (if available from ECM).
Gen Battery Voltage displays the DC voltage of the generator starting battery(ies) as measured by the controller.
ECM Battery Voltage displays the DC voltage of the engine starting battery(ies) as reported from the ECM.
Oil Temperature displays the engine oil temperature.
Coolant Pressure displays for the engine coolant pressure.
Fuel Pressure displays the fuel line pressure at the generator set inlet for gas-powered models.
Fuel Temperature displays the fuel supply temperature.
Fuel Used Last Run displays the accumulated amount of fuel used since last reset (if available from ECM).
Crankcase Pressure displays the engine crankcase pressure.
Intake Air Pressure displays the engine intake manifold air pressure if available.
Intake Air Temperature displays the engine intake manifold air temperature if available.
2.10.3 Overview Submenu
Generator Status:
Average Volts Line-to-Line. For three-phase configurations the average line-to-line voltage of L1, L2, and L3 is
displayed. Single-phase configurations show the L1-L2 voltage.
Average Current value displays as the average for three-phase configurations or the current value for L1-L2 with
single-phase configurations.
Frequency (Hz) value displays for the output AC voltage.
Engine Status:
Coolant Temperature displays the engine coolant temperature.
Oil Pressure displays the engine oil pressure.
Battery Voltage displays the DC voltage of the engine starting battery(ies).
System Status:
Fuel Pressure displays fuel injection pressure.
Total Power displays the generator operating power rating in kW.
Engine Run Time displays the total run time hours.

Table of Contents

Other manuals for Kohler 16EKOZD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 16EKOZD and is the answer not in the manual?

Kohler 16EKOZD Specifications

General IconGeneral
BrandKohler
Model16EKOZD
CategoryPortable Generator
LanguageEnglish

Related product manuals