TP-6905 9/21 27Section 2 Generator Set Operation
Fault (RDC2) CheckCondition
Fault
(OnCuer Plus)
Oil Pres Low
Shutdwn
Low Oil Pressure The engine ECM indicates low oil pressure.
Note: The low oil pressure shutdown does not
protect against low oil level. Check the engine oil
level regularly as recommended in Section 5.
Check for signs of leaks in the
lubrication system.
Check the oil level and add oil if
the level is low.
Contact an authorized dealer for
service.
Over Crank
Shutdwn
Over Crank Three unsuccessful starting attempts. Check the fuel supply, spark plug,
and battery.
Check for loose connections.
Contact an authorized dealer for
service.
Volts L1-L2 High
Shutdwn
Generator
Voltage AB High
Generator Voltage High. Output voltage exceeds
120% of the system nominal voltage for more
than 2 seconds.
Contact an authorized dealer for
service.
Volts L1-L2 Low
Shutdwn
Generator
Voltage AB Low
Generator V oltage Low. Output voltage falls
below 80% of the nominal system voltage for
more than 10 seconds.
Reduce the load by turning off
appliances and restart the
generator set.
Contact an authorized dealer for
service.
Volts L2-L3 High
Shutdwn
Generator
Voltage BC High
Generator Voltage High. Output voltage exceeds
120% of the system nominal voltage for more
than 2 seconds.
Contact an authorized dealer for
service.
Volts L2-L3 Low
Shutdwn
Generator
Voltage BC Low
Generator V oltage Low. Output voltage falls
below 80% of the nominal system voltage for
more than 10 seconds.
Reduce the load by turning off
appliances and restart the
generator set.
Contact an authorized dealer for
service.
Volts L3-L1 High
Shutdwn
Generator
Voltage CA High
Generator Voltage High. Output voltage exceeds
120% of the system nominal voltage for more
than 2 seconds.
Contact an authorized dealer for
service.
Volts L3-L1 Low
Shutdwn
Generator
Voltage CA Low
Generator V oltage Low. Output voltage falls
below 80% of the nominal system voltage for
more than 10 seconds.
Reduce the load by turning off
appliances and restart the
generator set.
Contact an authorized dealer for
service.
Figure 2-5 Controller Fault Messages