TP-6905 9/21 49Section 3 RDC2 Controller Operation
3.19 Load Control Menus
The Load Control menu displays the status of the load
management inputs and outputs, and allows a test of the
load management output relays. This menu appears
only if a load management device is connected.
Generator current is displayed as a percent of the
maximum generator capacity. The load management
device adds and sheds loads based on the generator
current.
The test function cycles the relays in the order of t heir
priority. For detailed information about load
management operation, refer to the instructions
provided with the load shed kit or the RXT Transfer
Switch Operation and Installation Manual.
Input 1:
In/Active
Output 1:
Add/Shed
Input 2:
In/Active
Output 2:
Add/Shed
Output 3:
Add/Shed
Output 4:
Add/Shed
Output 5:
Add/Shed
Output 6:
Add/Shed
Test Outputs
Push Select (blinking)
<- - Return
tp6810
Load - - >
Control
Load - - >
Control 1
<- - Return
Generator
Current: 123 %
Figure 3-23 Load Control Status Menu