TP-6905 9/2128 Section 2 Generator Set Operation
2.6.5 Status and Notice Messages
The Status and Notice messages shown in Figure 2-6
are displayed during generator set operation. These
informational messages do not indicate faults.
Message Type Description
Advance Diagnostic Active Status During any exercise mode, shutdown occurs due to any other
condition(Fault) excluding Emergency Shutdown, Main Power
Overloaded Shutdown, Low Cranking Voltage Shutdown.
Advance Diagnostic Active Ended Status Advance Diagnostic mode is ended
Always On Notice Any of the following optional boards are connected to controller
1. LCM
2. PIM
Ats Exercise Active Notice The generator is in exercise mode.
ATS Exercise mode End Prematurely Status Exercise mode ends prematurely.
Ats Loaded Test Active Status The ATS contactor position is source2 and user places the
controller in RUN mode.
Ats Position Source 1 selected Status The ATS contactor position is source1.
Ats Position Source 2 selected Status The ATS contactor position is source2.
ATS Test End Status ATS Test ended.
Ats Test Ended Prematurely Status ATS Test ended prematurely.
Ats Unloaded Test Active Status Generator is started by pressing RUN Button.
Auto Recovery Status Unit has reset due to unexpected error.
Backup Parameter Loaded Status Test event log command is initiated from Site Tech.
Default Parameters Loaded Status When the engine stops, status is updated.
Diagnostic Exercise Active Status Variable speed exercise is running.
Emergency Power System Supplying
Load
Notice The utility power is absent and the generator is powered on.
This notice is displayed on SiteTech.
Engine Cool Down Active Notice The generator is in cool down mode.
Engine Start Delay Active Notice The engine start delay is active.
Engine Started Status When the engine starts, status is updated.
Engine Stopped Status When the engine stops, status is updated.
Exercise mode End Status Exercise mode ended.
File System Error Status Parameter/event saving fails after 3 retries.
Forced to Auto Status Status Mode has changed to AUTO mode.
Generator Running Notice The engine is started and a valid engine speed has been
achieved. This notice is displayed in SiteTech.
Load Priority X Shed Notice Priority X (1- 6) load with is disconnected.
Loaded Full Speed Exercise Active Status Loaded full speed exercise is running.
Maintenance Timer Reset Status The user has reset the maintenance timer.
Normal Power Source Unavailable Notice Utility power is unavailable.
Remote Start Status The remote start switch is pressed.
Unloaded Full Speed Exercise Active Status Unloaded full speed exercise is running.
Figure 2-6 Status and Notice Messages