EasyManuals Logo
Home>Kohler>Plumbing Product>6EFKD

Kohler 6EFKD User Manual

Kohler 6EFKD
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
2 TT-1617 12/13
Procedure
1. Remove the generator set from service.
1.1 Push the generator set power button OFF.
1.2 Disconnect power to the battery charger, if
equipped.
1.3 Disconnect the generator set engine starting
battery, negative (--) lead first.
2. Remove the sound shield, if equipped.
2.1 Remove the three 5/16 in. x 2.5 in. bolts from the
sound shield roof. See Figure 1.
1
GM55219C
1. 5/16 in. x 2.5 in. bolts (qty. 3)
Top View
Figure 1 Roof Bolt Removal
2.2 Release the two latches on the service side door
to remove the service-side door. See Figure 2.
1
1. Latches (qty. 2)
GM55219C
Service-Side View
Figure 2 Service-Side Door Removal
2.3 Remove the 5/16 in. x 1.75 in. bolt to remove the
engine end door. See Figure 3.
1
1. 5/16 in. x 1.75 in. bolt
GM55219C
Engine-End
V
iew
Figure 3 Engine-End Door Removal
2.4 Remove the 5/16 in. x 1.75 in. bolts to remove the
exhaust panel and the generator-end door. S ee
Figure 4.
1
1. 5/16 in. x 1.75 in. bolt on exhaust panel
2. 5/16 in. x 1.75 in. bolt on generator-end door
GM55219C
Generator-End View
2
Figure 4 Exhaust Panel and Generator-End Door
Removal
2.5 Remove the two 5/16 in. x 0.625 in. bolts on the
nonservice-side door. After these bolts are
removed, remove the roof and remaining panels.
1
1. 5/16 in. x 0.625 in. bolts (qty. 2)
GM55219C
Nonservice-Side View
Figure 5 Nonservice-Side Door Removal