Operating fluids and maintenance Operation and Maintenance Manual
Lubricants and operating materials
Fig. 28: The correlation between TBN and sulfur in fuel
1 TBN 3 If TBN <8 mgKOH/g, the
engine oil should be replaced
as soon as possible.
5 recommended TBN [mg
KOH/g]
2 ppm sulfur 4 with TBN [mg KOH/g]
Viscosity class:
The viscosity class has to be selected on the basis of the cold start temperature.
The following viscosity classes are permitted for the engines: 5W30, 5W40,
10W30, 10W40 and 15W40. The change intervals according to oil category must
be observed.
Difficulty factors
Difficulty factors can be:
Frequent cold starts
Environmental influences
Operating temperature
Dust
High humidity
Long standstill times
If there are difficulty factors or difficult usage conditions, the oil change and filter
change must be performed according to the following table.
Engine oil change intervals:
The change intervals are defined as follows:
Basic oil change interval * Factor oil category * Factor sulfur content = change
interval
The basic oil change interval is defined in the maintenance tables.
The factor “oil category”:
Lubricant category Oil change factor (factor 1)
Lubricant category 1
1/4” => reduces the maintenance interval
by one quarter
42
© 2017 by Kohler Co. All rights reserved.
KD27V12 33521029401_3_1 en 2017-07-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD27V12 and is the answer not in the manual?

Kohler KD27V12 Specifications

General IconGeneral
BrandKohler
ModelKD27V12
CategoryEngine
LanguageEnglish

Related product manuals