13NOMENCLATURE
ENGLISH
BEasy Checker
When an abnormal condition occurs with a part monitored
by the easy checker while the engine is running, a lamp
flashes to warn the operator of the impending trouble.
BControl Box
(1) Charge warning lamp
(2) Water temperature-overheat warning lamp, flashes on when
cooling water rises to 112 to 118 C.
(3) Engine oil pressure drop warning lamp, flashes on below 39
to 59 kPa (0.4 to 0.6 kgf/cm ) oil pressure.
(4) Glow plug lamp
(1) Excitation unit
(2) Emergency relay
(3) Starter relay
(4) Glow relay
(5) Glow lamp timer
(6) Relay
(7) Relay (Solenoid)