25PERIODIC SERVICE
ENGLISH
A Connect the charger positive terminal to the battery
positive terminal, and negative to the negative.
A When disconnecting the cable from the battery, start
with the negative terminal first.
When connecting the cable to the battery, start with
the positive terminal first.
If reversed, the contact of tools on the battery may
cause a short.
BDirection for long term storage
1. When storing the engine for long periods of time,
remove the battery, adjust the electrolyte to the
proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
ELECTRIC WIRING
CAUTION
To avoid personal injury:
C Shorting of electric cable or wiring
may cause a fire.
A Check to see if electric cables
and wiring are swollen, hardened
or cracked.
A Keep dust and water away from
all power connections.
Loose wiring terminal parts,
make bad connections. Be sure
to repair them before starting the
engine.
Damaged wiring reduces the capacity of electrical parts.
Change or repair damaged wiring immediately.
(1) Thick cable red(+)
(2) Battery case
(3) Earth cable black(-)
(1) Plug (A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"