2M8/2M9
1-4-48
(2-5) U010XX error code table: G3 transmission
Error code Description
U01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001 Function of the unit differs from that indicated by a DIS signal.
U01016 An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01019 No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020 No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022 No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01028 T5 time-out was detected during ECM transmission (ECM).
U01052 A DCN signal was received after transmission of an RR signal (ECM).
U01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01092 During transmission in V.34 mode, communication was interrupted because of an impos-
sible combination of the symbol speed and communication speed.
U01093 A DCN or other inappropriate signal was received during phase B of transmission.
U01094 The preset number of command retransfers for DCS/NSS signals was exceeded during
phase B of transmission.
U01095 No relevant signal was received after transmission of a PPS (Q) signal during phase D of
transmission, and the preset number of command transfers was exceeded.
U01096 A DCN signal or invalid command was received during phase D of transmission.
U01097 The preset number of command retransfers was exceeded after transmission of an RR
signal or no response.