EasyManuals Logo
Home>Lantronix>Server>xDirect

Lantronix xDirect User Manual

Lantronix xDirect
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
4: Using DeviceInstaller
xDirect User Guide 21
Next Step
Now that the xDirect unit has an IP address and other initial settings, you can configure it.
1. Double-click the unit in the list. Details about the unit display.
2. You have the following options:
To configure the unit using a Web browser, click the Web Configuration tab. The Lantronix
Web Manager window displays in your browser. Continue with Chapter 5: Configuration
Using Web Manager.
Note: To assign Expert and Security settings, you must use the Setup Mode
window in a Telnet session.
To configure the unit using a Telnet session, click the Telnet Configuration tab. The Setup
Mode window displays. Continue with Chapter 6: Configuration Via Telnet or Serial Port
(Setup Mode).
Assigning the IP Address: Serial Port Login
To assign the IP address and other network settings using a serial connection:
1. Connect a console terminal or a PC running a terminal emulation program to the unit's serial
port. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow
control.
2. To enter Setup Mode, cycle the unit's power (power off and back on). After power-up, the self-
test begins and the red Diagnostic LED starts blinking. You have one second to enter three
lowercase x characters.
Note: The easiest way to enter Setup Mode is to hold down the x key at the terminal
(or emulation) while powering up the unit.
3. Select 0 (Server Configuration) and follow the prompts until you get to IP address.
4. Enter the new IP address, subnet mask, and gateway (if applicable).
5. Do one of the following:
Continue with Chapter 6: Configuration Via Telnet or Serial Port (Setup Mode).
Select 9 to save and exit Setup Mode. The unit performs a power reset.
Supports 485 Non-configurable field. xDirect supports the RS-485 protocol. Displays:
False for XDT232.
True for XDT485.
Supports 921K Baud Rate Non-configurable field. Displays True. xDirect supports baud rates up to
921600 bits per second (bps).
Supports HTTP Server Non-configurable field. Displays True.
Supports HTTP Setup Non-configurable field. Displays True.
Supports 230K Baud Rate Non-configurable field. Displays True. xDirect supports a baud rate of
230400.
Supports GPIO Non-configurable field. Displays False, indicating the xDirect does not
support General Purpose Input Output (GPIO).
Current Settings (continued) Description

Table of Contents

Other manuals for Lantronix xDirect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix xDirect and is the answer not in the manual?

Lantronix xDirect Specifications

General IconGeneral
ManualYes
Quantity per pack1 pc(s)
Connector 1RS232/422/485
Connector 2DB9F
Connector 1 genderFemale
CertificationCE, RoHS
Product colorBlack, Silver
Sustainability certificatesRoHS
Input voltage100 - 240 V

Related product manuals