EasyManuals Logo
Home>Lantronix>Server>xDirect

Lantronix xDirect User Manual

Lantronix xDirect
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
xDirect User Guide 39
7: Setup Mode: Server Configuration
This chapter explains how to configure the network settings.
Note: Current values display in parentheses.
Server Configuration (Option 0)
The unit’s basic network parameters display when you select Server configuration (option 0).
The IP Address, Set Gateway IP Address, and Netmask fields display the current values.
Figure 7-1 Network Settings
IP Address : (000) .(000) .(000) .(000)
Set Gateway IP Address (N) ?
Netmask: Number of Bits for Host Part (0=default) (0)
Set DNS Server IP addr (N) ?
Change Telnet/Web Manager password (N) ?
Change DHCP device name (not set) ? (N) ?
Enable DHCP FQDN option : (N) ?
IP Address
If DHCP is not used to assign IP addresses, enter the IP address manually. The IP address must
be set to a unique value in the network. Enter each octet and press Enter between each section.
The current value displays in parentheses.
IP Address : (000) (000) (000) (000) _
If DHCP is used, the third octet of the IP address sets the BootP/DHCP/AutoIP options. The
following table shows the bits you can manually configure to force the xDirect to disable AutoIP,
DHCP, or BootP. To disable an option, set the appropriate bit.
Table 7-2 BootP/DHCP/AutoIP options
For example, if the third octet is 0.0.5.0, the AutoIP and BootP options are disabled; only DHCP is
enabled. (The value 5 results from adding the binary equivalents of 0 and 2.) This is the most
common setting when using DHCP.
Options Bit Value
AutoIP 0
1
DHCP 1
2
BootP 2
4

Table of Contents

Other manuals for Lantronix xDirect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix xDirect and is the answer not in the manual?

Lantronix xDirect Specifications

General IconGeneral
ManualYes
Quantity per pack1 pc(s)
Connector 1RS232/422/485
Connector 2DB9F
Connector 1 genderFemale
CertificationCE, RoHS
Product colorBlack, Silver
Sustainability certificatesRoHS
Input voltage100 - 240 V

Related product manuals