LAUNCH CNC-603A Injector Cleaner & Tester User Manual
11
Mode 1 of Auto. Test
Set the pressure: start
the fuel pump to adjust
pressure to setpoint
Inject normally for 15s
Observe for 30s
RMP: 650rmp, pulse
width: 3ms, counts:
2000
Observe for 30s
Drain for 30s
Observe for 30s
Drain for 30s
RMP: 6000rmp, pulse
width: 3ms, counts:
2500
Observe for 30s
Drain for 30s
Observe injection angle and
degree of atomization
Observe blockage and dripple,
normal injection test ended
Observe idle
conditions
Drain after idle speed
test
Drain after medium
speed test
Observe high
speed conditions
Drain after high
speed test
A
A
Drain for 30s
RMP: 4500rmp, pulse
width: 5ms, counts: 1700
Observe medium
speed conditions