Page 2
SPECIFICATIONS
General
Data
Model No. 13HPX−018 13HPX−024 13HPX−030 13HPX−036
Nominal Tonnage 1.5 2 2.5 3
1
Sound Rating Number 76 76 76 76
Connections
(sweat)
Liquid line o.d. − in. 3/8 3/8 3/8 3/8
Vapor line o.d. − in. 3/4 3/4 3/4 7/8
2
Refrigerant R−410A charge furnished 7 lbs. 4 oz. 7 lbs. 8 oz. 8 lbs. 6 oz. 8 lbs. 12 oz.
Outdoor
Coil
Net face area
sq. ft.
Outer coil 15.21 15.21 13.30 15.21
Inner coil − − − − − − 12.60 14.50
Tube diameter − in. 5/16 5/16 5/16 5/16
No. of rows 1 1 2 2
Fins per inch 22 22 22 22
Outdoor
Fan
Diameter − in. 18 18 18 18
No. of Blades 3 3 4 4
Motor hp 1/5 1/5 1/5 1/5
Cfm 2400 2400 2440 2450
Rpm 1130 1130 1095 1100
Watts 166 166 194 190
Shipping Data − lbs. 1 package 140 150 170 180
ELECTRICAL DATA
Line voltage data − 60 hz − 1ph 208/230V 208/230V 208/230V 208/230V
3
Maximum overcurrent protection (amps) 20 30 30 35
4
Minimum circuit ampacity 12.3 17.9 18.7 21.9
Compressor
Rated Load Amps
9.0 13.5 14.1 16.7
Locked Rotor Amps
48 58.3 73 79
Power Factor
0.96 0.97 0.98 0.98
Outdoor
Fan Motor
Full Load Amps
1.1 1.1 1.1 1.1
Locked Rotor Amps
1.9 1.9 1.9 1.9
OPTIONAL ACCESSORIES − must be ordered extra
Compressor Crankcase Heater 93M05 S S S S
Compressor Hard Start Kit
10J42 S
88M91 S S S
Compressor Low Ambient Cut−Off 45F08 S S S S
Compressor Sound Cover 69J03 S S S S
Freezestat
3/8 in. tubing 93G35 S S S S
5/8 in. tubing 50A93 S S S S
Hail Guards
92M89 S S S
92M88 S
5
Low Ambient Kit 54M89 S S S S
Low Pressure Switch Bypass Thermostat 13W07 S S S S
Mild Weather Kit 33M07 S S S S
Monitor Kit − Service Light 76F53 S S S S
Mounting Base 69J06 S S S S
Outdoor
Thermostat Kit
Thermostat 56A87 S S S S
Mounting Box 31461 S S S S
Refrigerant
Line Sets
L15−41−20
L15−41−30
L15−41−40
L15−41−50
S S S
L15−65−30 L15−65−40
L15−65−50
S
Time Delay Relay Kit 58M81 S S S S
Unit Stand−Off Kit 94J45 S S S S
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Sound Rating Number rated in accordance with test conditions included in ARI Standard 270.
2
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
3
HACR type circuit breaker or fuse.
4
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.