EasyManuals Logo
Home>Lennox>Heat Pump>14HPX-036-230-17

Lennox 14HPX-036-230-17 User Manual

Lennox 14HPX-036-230-17
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Page 4
Electrical Data
208/230V-60 Hz-1 Ph
Model Number Label Rev.
Unit Compressor Condenser Fan
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor HP
Nominal
RPM
Full Load
Amps
(FLA)
Locked
Rotor
Amps
(LRA)
14HPX-018-230-01
1.0 20 12.3 8.97 48.0 1/5 1075 1.1 1.4
2.0. 3,0 &
4.0
20 11.9 8.97 48.0 1/10 1075 .70 1.4
14HPX-018-230-10 1.0 20 11.9 8.97 48.0 1/10 1075 .70 1.4
14HPX-018-230-11 1.0 20 11.9 8.97 48.0 1/10 1075 .70 1.4
14HPX-018-230-12 1.0 20 11.9 10.18 48.0 1/10 1075 .70 1.4
14HPX-018-230-13 1.0 20 11.9 10.18 48.0 1/10 1075 .70 1.4
14HPX-018-230-14 1.0 20 11.9 10.18 48.0 1/10 1075 .70 1.4
14HPX-018-230-15 1.0 20 11.9 10.18 48.0 1/10 1075 .70 1.4
14HPX-018-230-17
1.0, 2.0 &
3.0
20 12.3 8.96 48.0 1/6 825 1.1 1.87
14HPX-018-230-18
1.0 20 12.3 8.96 48.0 1/6 825 1.1 1.87
2.0 20 12.2 9.0 48.0 1/6 825 1.0 1.87
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
208/230V-60 Hz-1 Ph
Model Number Label Rev.
Unit Compressor Condenser Fan
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor HP
Nominal
RPM
Full Load
Amps
(FLA)
Locked
Rotor
Amps
(LRA)
14HPX-024-230-01
1.0 30 17.9 13.46 58.0 1/5 1075 1.1 1.4
2.0 & 3.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-10 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-11 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-12 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-13 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-14 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-15 1.0 30 17.5 13.46 58.0 1/10 1075 .70 1.4
14HPX-024-230-17
1.0, 2.0,
3.0 & 4.0
30 17.9 13.44 58.0 1/6 825 1.1 1.87
14HPX-024-230-18
1.0 30 17.9 13.44 58.0 1/6 825 1.1 1.87
2.0 30 17.9 17.9 58.0 1/6 825 1.1 1.87
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox 14HPX-036-230-17 and is the answer not in the manual?

Lennox 14HPX-036-230-17 Specifications

General IconGeneral
BrandLennox
Model14HPX-036-230-17
CategoryHeat Pump
LanguageEnglish

Related product manuals