# 48306B006 Page 21
Figure 14
Single Phase Wiring Diagram P/N 46330-002
OUTDOOR
FAN
DUAL
CAPACITOR
PURPLE
BLACK
BLACK
ORANGE
RED
YELLOW
RED
F
C
H
COMPRESSOR
R
SC
BLACK
COMPRESSOR
CONTACTOR
CRANKCASE HEATER
DEFROST
CONTROL
THERMOSTAT
C
R
W1
O
Y1
FAN
O-OUT
LO-PS
DF
Y1 OUT
COMMON
W1
C
L
R
O
Y1
2
2
HI-PS
BLUE
1
208-230/60/1
L2
L1
GROUND
GROUND
LUG
S40
DEFROST
THERMOSTAT
REVERSING
VALVE
1
L1
208-230/60/1
CMC1
FAN
THERMOSTAT
C
R
W1
O
Y1
L1
S6
K1
2
2
O-OUT
LO-PS
W1
C
L
R
O
Y1
DF
COMMON
Y1 OUT
HI-PS
BLUE
H
C
F
C12
PURPLE
B4
CMC1
BLACK
FAN
RED
S40
EQUIPMENT
GROUND
HR1
L2
K1-1
BLACK
YELLOW
RED
BLACK
C
S
R
ORANGE
B1
LO-PS
S87
LOW PRESSURE
SWITCH
S4
HIGH PRESSURE
SWITCH
HI-PS
DESCRIPTION
KEY COMPONENT
B1 COMPRESSOR
B4
MOTOR - OUTDOOR FAN
C12 CAPACITOR - DUAL
HR1 HEATER - COMPRESSOR
K1-1 CONTACTOR - COMPRESSOR
S4 SWITCH - HIGH PRESSURE
S6 SWITCH - DEFROST
S40 THERMOSTAT - CRANKCASE
CMC1 CONTROL-DEFROST
S87 SWITCH - LOW PRESSURE
L1 VALVE - REVERSING
WARNING--
ELECTRIC SHOCK HAZARD, CAN CAUSE INJURY OR DEATH. UNIT MUST
BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES.
LINE VOLTAGE FACTORY INSTALLED
LINE VOLTAGE FIELD INSTALLED
24 VOLT FACTORY INSTALLED
CLASS II VOLTAGE FIELD INSTALLED
1
FOR USE WITH COPPER CONDUCTORS ONLY. REFER TO UNIT
RATING PLATE FOR MINIMUM CIRCUIT AMPACITY AND MAXIMUM
OVERCURRENT PROTECTION SIZE.
2
CONNECTION MUST BE JUMPERED WHEN OPTIONAL SWITCH IS NOT USED.
NOTE:
DO NOT CONNECT C (COMMON) CONNECTION BETWEEN THE INDOOR
UNIT AND THERMOSTAT EXCEPT WHEN REQUIRED BY THE INDOOR
THERMOSTAT. REFER TO THERMOSTAT INSTALLATION INSTRUCTIONS.
C (COMMON) CONNECTION BETWEEN INDOOR UNIT AND OUTDOOR
UNIT REQUIRED FOR PROPER OPERATION.