SPECIFICATIONS
Model No. 80UHG2(X)-45 80UHG2(X)-60 80UHG3(X)-60 80UHG2(X)-75 80UHG3(X)-75 80UHG4(X)-75
Input Btuh (kW) 45,000 (13.2) 60,000 (17.6) 75,000 (22.0)
Output Btuh (kW) 36,900 (10.8) 49,200 (14.4) 61,700 (18.1) 61,700 (18.1)
A.F.U.E. 80.1% 80.5% 80.1% 80.0%
California Seasonal Efficiency 75.4% 76.4% 75.9% 76.8% 76.8% 76.3%
Flue size connection diameter in. (mm) round 3 (76) 4 (102)
Temperature rise range _F (_C) 30 - 60 (17 - 33) 45 - 75 (25 - 42)
High static cert. by A.G.A./C.G.A. in wg. (Pa) .50 (125)
Gas Piping Size I.P.S. Natural or LPG/propane 1/2 (13)
Blower wheel nominal
in. 9 x 7 10 x 7 9 x 7 10 x 7 12 x 8
Blower
wheel
nominal
diameter x width
mm 229 x 178 254 x 178 229 x 178 254 x 178 305 x 203
Blower motor output hp (W) 1/4 (187) 1/3 (224) 1/4 (187) 1/3 (224) 1/2 (373)
Nominal coolin
g
Tons 1, 1-1/2 or 2 2, 2-1/2 or 3 1, 1-1/2 or 2 2, 2-1/2 or 3
2, 2-1/2, 3,
3-1/2 or 4
Nominal
cooling
that can be added
kW 3.5, 5.3 or 7.0 7.0, 8.8 or 10.6 3.5, 5.3 or7.0 7.0, 8.8 or 10.6
7.0, 8.8, 10.6,
12.3 or 14.1
Shipping weight lbs. (kg) 1 package 130 (59) 135 (61) 140 (64)
Electrical Characteristics 120 volts 60 hertz 1 phase (less than 12 amps) All models
Optional Accessories (Must Be Ordered Extra)
LPG/propane kit LB-69845L (38K84)
Twinning Kit 15L38 11lbs. (5 kg)
U
p
−Flow/Horizontal Filter and Filter Rack Kits Sin
g
le
(
32J02
)
Ten Pack
(
66K64
)
Up−Flow/Horizontal
Filter
and
Filter
Rack
Kits
No. & sizeoffilters− in. (mm)
Single
(32J02)
Ten
Pack
(66K64)
(1) 16 x 20 x 1 (406 x 508 x 25)
Sidewall Power Venting Kit 79J15 25 lbs. (11 kg)
Hanging Bracket Kit LB-69957 (46J66) 15 lbs. (8 kg)
SPECIFICATIONS
Model No. 80UHG3/4(X)-100 80UHG4/5(X)-100 80UHG3/4(X)-120 80UHG4/5(X)-120
Input Btuh (kW) 100,000 (29.3) 120,000 (35.2)
Output Btuh (kW)
82,000 (24.0)
98,400 (28.8)
A.F.U.E. 80.1% 80.0% 80.0% 80.1%
California Seasonal Efficiency 76.5% 77.0% Not Available 75.5%
Flue size connection diameter in. (mm) round 4 (102)
Temperature rise range _F (_C) 45 - 75 (25 - 42) 35 - 65 (19 - 36) 45 - 75 (25 - 42)
High static certified by A.G.A./C.G.A. in wg. (Pa) .50 (125) .65 (162) .50 (125)
Gas Piping Size I.P.S. Natural or LPG/propane 1/2 (13)
Blower wheel nominal
in. 12 x 8 12 x 9 12 x 8 12 x 9
Blower
wheel
nominal
diameter x width
mm 305 x 203 305 x 229 305 x 203 305 x 229
Blower motor output hp (W) 1/2 (373) 3/4 (560) 1/2 (373) 3/4 (560)
Nominal coolin
g
Tons 2, 2-1/2, 3, 3-1/2 or 4 3-1/2, 4, 5 or 6 2, 2-1/2, 3, 3-1/2 or 4 3-1/2, 4, 5 or 6
Nominal
cooling
that can be added
kW 7.0, 8.8, 10.6, 12.3 or 14.1 12.3, 14.1, 17.6 or 21.1 7.0, 8.8, 10.6, 12.3 or 14.1 12.3, 14.1, 17.6or21.1
Shipping weight lbs. (kg) 1 package 175 (79)
Electrical Characteristics 120 volts 60 hertz 1 phase (less than 12 amps) All models
Optional Accessories (Must Be Ordered Extra)
LPG/propane kit LB-69845K (81J14)
Twinning Kit 15L38 (5 kg)
U
p
−Flow/Horizontal Filter and Filter Rack Kits Sin
g
le
(
46J14
)
Ten Pack
(
66K65
)
Up−Flow/Horizontal
Filter
and
Filter
Rack
Kits
No. & sizeoffilters− in. (mm)
Single
(46J14)
Ten
Pack
(66K65)
(1) 20 x 20 x 1 (508 x 508 x 25)
Sidewall Power Venting Kit 79J15 25 lbs. (11 kg)
Hanging Bracket Kit LB-69957 (46J66) 15 lbs. (8 kg)
Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
Polyurethane frame type filter is furnished with kit.