H-Low Ambient Kit (all units)
The optional low ambient kit (figure 53) allows for mechan
ical cooling operation at low outdoor temperature.NOTE-
See CAUTION.
CAUTION
Compressor monitor (Low Ambient Lockout Switch)
S3 cannot be used with optional low ambient kit.Com
pressor monitor MUST be disconnected before allow
ing low ambient kit to be used.
The components included in the low ambient kit vary from
unit to unit.Low ambient kits may include any combination
of a pressure switch, a low ambient thermostat or a relay.
WARNING
Electrical shock hazard. Low ambient kit wiring
changes depending on unit size. Depending on the
application, low ambient controls may be wired to low
voltage or line voltage. Be sure to disconnect power
to unit before servicing. Then check unit wiring dia
gram and become familiar with low ambient wiring be
fore proceeding.
The pressure switch, if used, is connected to the condens
er fan and the compressor discharge line. The pressure
switch senses a drop in outdoor temperature by monitor
ing the pressure of the discharge line. When discharge line
pressure drops below a preset limit, the pressure switch
opens the circuit to the condenser fan. With the condenser
fan deenergized, the discharge pressure will slowly in
crease. When discharge pressure increases above a pre
set limit the pressure switch closes the circuit to the con
denser fan and the fan resumes operation. The pressure
switch will continue to cycle the fan in this fashion as long
as low ambient conditions exist.
The low ambient thermostat, if used, is connected to the
second stage compressor. The switch monitors outdoor
temperature conditions and opens the circuit to the sec
ond stage compressor when outdoor temperture drops
below a preset limit. The second stage compressor re
mains disconnected from the circuit until outdoor tempera
ture rises above the preset limit.
The low ambient kit relay, if used, is typically used to sense
a call for compressor demand. When the relay coil is ener
gized, the contacts switch to complete a circuit through the
low ambient pressure switch.
FIGURE 53
TYPICAL INSTALLATION
LOW AMBIENT
PRESSURE SWITCH
HIGH PRESSURE
SWITCH
COMPRESSOR
DISCHARGE
LINE
LOSS OF
CHARGE
SWITCH
VALVE
DEPRESSOR TEE
SHOCK
LOOP
LOW AMBIENT KIT
Refer to low ambient kit installation instructions for de
tailed installation and operation information. Low ambient
kit wiring is shown on the unit wiring digrams in back of this
manual.
I-Status Panels SP11 and SSP11
Optional status panels allow remote monitoring of system
operation.Two types of panels are available.The SP11 (fig
ure 54) provides system readout only.The SSP11 switching
status panel (figure 55) is a combination switching subbase
and system readout.The SSP11 also has an After Hours
Timer" to override the unoccupied mode (night heating set
back / cooling setup).
FIGURE 54
SP11 STATUS PANEL
Cool Mode
Heat Mode
Compressor 1
Compressor 2
No Heat
Filter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CHA16 and is the answer not in the manual?

Lennox CHA16 Specifications

General IconGeneral
BrandLennox
ModelCHA16
CategoryAir Conditioner
LanguageEnglish

Related product manuals