OPTIONAL ACCESSORIES CHA/CHP16
Model No. Ć024 Ć030 -036 -048 -060
Economizer with Gravity Exhaust Dampers
(D Fl ) Itlldi tli bit i
3 position REMD16-41 - 48 lbs. (22 kg) REMD16-65 - 66 lbs. (30 kg)
yp
(Down-Flow) Ċ Installs directly in cabinet, recircuĆ
lated air dam
p
ers with
p
ressure o
p
erated
g
ravit
y
US
Fully Modulating REMD16M-41 - 48 lbs. (22 kg) REMD16M-65 - 66 lbs. (30 kg)
lated
air
dampers
with
pressure
operated
gravity
exhaust damper, formed, gasketed damper blades,
nylon bearings 24v damper motor has adjustable
US
Only
Indoor Filter (1) 16 x 25 x 1 (406 x 635 x 25) (1) 20 x 25 x 1 (508 x 635 x 25)
ny
l
on
b
ear
i
ngs,
24
v
d
amper mo
t
or
h
as a
dj
us
t
a
bl
e
minimum position switch, electronic discharge air
sensor adjustable outdoor air enthalpy control Uti
Outdoor Filter (1) 14 x 25 x 1 (356 x 635 x 25) (1) 18 x 25 x 1 (457 x 635 x 25)
p, g
sensor, adjustable outdoor air enthalpy control. UtiĆ
lizes filter furnished with unit, filter rack will acce
p
t
Fully Modulating REMD16M-41S - 85 lbs. (39 kg) REMD16M-65S- 105 lbs. (48 kg)
lizes
filter
furnished
with
unit
,
filter
rack
will
accept
up to 2 in. (51 mm) filter. Removable exhaust air
hood and outdoor air intake hood with cleanable
Canada
Only
Indoor Filter (1) 16 x 25 x 1 (406 x 635 x 25) (1) 20 x 25 x 1 (508 x 635 x 25)
h
oo
d
an
d
ou
td
oor a
i
r
i
n
t
a
k
e
h
oo
d
w
ith
c
l
eana
bl
e
aluminum mesh filter. Choice of economizer conĆ
trols.
Only
Outdoor Filter (1) 19-3/8 x 15-3/4 x 1
(1) 19-7/8 x 22-3/4 x 1
(505 x 578 x 25)
Economi er Dampers (Hori ontal) Installs direct
3 position EMDH16-41 110 lbs. (50 kg) EMDH16-65 - 130 lbs. (59 kg)
Economizer Dampers (Horizontal) Ċ Installs direc
ly in cabinet, combination outdoor air and recircu
Ć
US
Fully Modulating EMDH16M-41 - 110 lbs. (50 kg) EMDH16M-65 - 130 lbs. (59 kg)
ly
in
cabinet
,
combination
outdoor
air
and
recircu
Ć
lated air damper, formed, gasketed damper blades,
nylon bearings, 24v damper motor has adjustable
ii iti ith l t i di h i
US
Only
Indoor Filter (1) 20 x 24 x 1 (508 x 610 x 25)
(1) 16 x 25 x 1 (406 x 635 x 25)
(1) 14 x 25 x1 (356 x 635 x 1)
yg,p j
minimum position switch, electronic discharge air
sensor, adjustable outdoor air enthalpy control. 1 in
Outdoor Filter (1) 8 x 24 x 1 (203 x 610 x 25) (1) 8 x 28 x 1 (203 x 711 x 25)
sensor
,
adjustable
outdoor
air
enthalpy
control
.
1
in
(25 mm) fiberglass filter furnished, filter rack will
t t 2 i (51 ) filt td i i t k
Fully Modulating EMDH16M-41S - 70 lbs. (32 kg) EMDH16M-65S - 86 lbs. (39 kg)
(25
mm)
fiberglass
filter
furnished,
filter
rack
will
accept up to 2 in. (51 mm) filter, outdoor air intake
hood with aluminum mesh filter Choice of econo
Ć
Canada
Ol
Indoor Filter (1) 20 x 20 x 1 (508 x 508 x 25) (1) 20 x 25 x 1 (508 x 635 x 25)
h
oo
d
w
ith
a
l
um
i
num mes
h
filt
er.
Ch
o
i
ce o
f
econoĆ
mizer controls.
Only
Outdoor Filter
(1) 16-1/2 x 21-3/4 x 1
(419 x 552 x 25)
(1) 22-1/2 x 25-1/4 x 1
(571 x 641 x 25)
Electric Heat Ċ Field installed, helix wound nichrome elements, time delay for eleĆ
ment staging, individual element limit controls, wiring harness, may be twoĆstage
controlled.
ECH16R - Supplemental thermal cutoff safety fuses and thermal
relay sequencer.
ECH16 - Supplemental secondary limits, heating control relay,
fuse block, thermal relay sequencer (20-25 kW
208/230v) and galvanized steel control box.
See Electric Heat Data Tables
Electric Heat Single Point Power Source Sub-Fuse Box Ċ Use with ECH16R
electric heaters, use in conjunction with ECH16 fuse box for single point power
source applications, installs internal to unit, fuses furnished, constructed of galvaĆ
nized steel with prepunched mounting holes
See Electric Heat Data Tables
Unit Single Point Power Source Sub Fuse Box Ċ Installs internal to unit, proĆ
vides sub-fusing to the unit, used in conjunction with ECH16 or ECH16R for single
point power source applications, fuses furnished, constructed of galvanized steel
with prepunched mounting holes and electrical inlet and outlet holes, hinged box
cover
See Electric Heat Data Tables
Enthalpy Control, Differential Ċ Used in conjunction with outdoor air enthalpy
control. Determines and selects which air has the lowest enthalpy. Return air enĆ
thalpy sensor field installs in economizer damper section
54G44
Gravity Exhaust Dampers Ċ For use with EMDH16. Pressure operated assembly
field installs in the return air duct adjacent to the economizer assembly. Includes
bird screen. - Net Weight
GEDH16-65 - 4 lbs. (2 kg)
Horizontal Filter Kit (Canada Only) Ċ For horizontal applications, painted steel
cabinet with filter access, disposable, pleated fiber filter furnished, number and
size of filter - Net Weight
HF16-46S - 18 lbs. (8 kg)
(1) 20 x 20 x 2 in.
(508 x 508 x 51 mm)
HF16-65S - 21 lbs. (10 kg)
(1) 20 x 25 x 2 in.
(508 x 635 x 51 mm)
Low Ambient Control Kit Ċ Units operate down to 30°F (-1°C) outdoor air temperĆ
ature in cooling mode without any additional controls. A Low Ambient Kit can be
field installed, enabling unit to operate properly down to 0°F (Ć17.7°C).
CHP16 LB-57113BM (27J00)
CHA16 LB-57113BC (24H77)
Roof Curb Power Entry Kit Ċ Allows power entry through
roof mounting frame knockouts provided in roof frame kit
1/2 in. (13 mm) 18H70
roo
f
moun
ti
ng
f
rame,
k
noc
k
ou
t
s prov
id
e
d
i
n roo
f
f
rame,
kit
contains 40 in. (1016 mm) armored conduit and installation
hardware two kits are required one for low voltage and one
1 in. (26 mm) 18H71
()
hardware, two kits are required, one for low voltage and one
for high voltage. See Dimension Drawing
1-1/2 in. (39 mm) 18H72
Roof Mounting Frame Ċ Nailer strip furnished, mates to unit, U.S. National RoofĆ
ing Contractors Approved, shipped knocked down. RMF16-41 may be used on
all sizes, with a slight unit overhang on CHP16-048 and CHP16-060 units - Net
Weight
NOTE (US Only) Ċ Sound Reduction Plate must be ordered separately for field
installation.
RMF16-41 - 75 lbs. (35 kg) 97G59
Plate (order separately) (73H80)
RMF16-41 - 75 lbs. (35 kg)
97G59
Plate (order separately)
(73H80)
RMF16-65 - 86 lbs.
(39 kg) 97G60
Plate (order separately)
(73H82)
Outdoor Air Damper Section Ċ For downĆflow applications,
dam
p
er assembl
y
re
p
laces blower access
p
anel, manuall
y
US Only
OAD16-41 - 12 lbs. (5 kg)
(1) 5 x 17 x 1 in.
(127 x 432 x 25 mm)
OAD16-65 - 12 lbs. (5 kg)
(1) 8 x 17 x 1 in.
(203 x 432 x 25 mm)
damper
assembly
replaces
blower
access
panel
,
manually
adjustable, 0 to 25% (fixed) outdoor air, outdoor air hood with
cleanable filter included, number and size of filter - Net Weight
Canada Only
OAD16-41S - 10 lbs. (5 kg)
(1) 14 x 6 x 1 in.
(356 x 152 x 25 mm)
OAD16-65S - 16 lbs. (7 kg)
(1) 18 x 6 x 1 in.
(457 x 152 x 25 mm)
Outdoor Air Damper Section Ċ For horizontal applications, installs in return air
duct adjacent to unit, manually adjustable (fixed) outdoor air - Net Weight
OAD3-46/65 - 8 lbs. (4 kg)
Outdoor Thermostat Kit Ċ Used to lock out some of the
electric heating elements on indoor units where two stage
control is applicable Outdoor thermostat maintains the
Thermostat Kit LB-29740BA (56A87)
con
t
ro
l
i
s app
li
ca
bl
e.
O
u
td
oor
th
ermos
t
a
t
ma
i
n
t
a
i
ns
th
e
heating load on the low power input as long as possible
before allowing the full power load to come on line
Mounting Box M-1595 (31461) / BM-10260 (33A09) Canada Only
Indoor filter is not furnished with economizer. REMD16 utilizes existing filter furnished with 16 unit.