Page 15
Right Side Vent Configuration
Side Vent
Sealing Plate
Side Vent
Sealing Gaskets
Street Elbows (2)
Intake
Exhaust
FIGURE 23
TABLE 5
OUTDOOR TERMINATION USAGE*
Input Size
Vent Pipe
Dia. in.
STANDARD CONCENTRIC
Flush Mount
Kit
Wall Kit
Field
Fabricated
1-1/2 inch 2 inch 3 inch
51W11 (US)
51W12 (CA)
2 inch 3 inch
71M80 (US)
444W92
(CA)
69M29 (US)
444W92
(CA)
60L46 (US)
444W93
(CA)
22G44 (US)
430G28
(CA)
44J40 (US)
481J20 (CA)
045
2
3
YES
YES
1
YES
5
YES
2
YES
N/A N/A
2-1/2
3
YES
YES
1
YES
5
YES
2
YES
3
3
YES
YES
1
YES
5
YES
2
YES
070
2 3YES YES
1
YES
5
YES
2
YES
2-1/2
3
YES
YES
1
YES
5
YES
2
YES
3
3
YES
YES
1
YES
5
YES
2
YES
090
2
3
YES
N/A
YES
5
YES
N/A
YES YES
2-1/2
3
YES
YES
5
YES
YES YES
3
3
YES
YES
5
YES
YES YES
110
2 YES YES
5
YES
YES YES
2-1/2 YES YES
5
YES
YES YES
3 YES YES
5
YES
YES YES
NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must
be included in total vent length calculations. See vent length tables.
* Kits must be properly installed according to kit instructions.
1Requires eld-provided outdoor 1-1/2” exhaust accelerator.
2Concentric kits 71M80 and 44W92 include 1-1/2” outdoor accelerator, when used with 045 and 070 input models.
3 Flush mount kit 51W11 and 51W12 includes 1-1/2 in. outdoor exhaust accelerator, required when used with 045, 070 and 090 input models.
4 Termination kits 30G28, 44W92, 4493 and 81J20 are certied to ULC S636 for use in Canada only.
5 See table 10 for vent accelerator requirements.