Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No. EL296DF045XE36BEL296DF070XE48BEL296DF090XE48CEL296DF110XE60C
AHRI Ref. No. 5625722 5625723 5940633 5625725
1
AFUE 96% 96% 96% 96%
High
Fire
Input - Btuh 44,000 66,000 88,000 110,000
Output - Btuh 43,000 64,000 85,000 106,000
Temperature rise range - °F 35-65 35-65 40-70 45-75
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Low
Fire
Input - Btuh 29,000 43,000 57,000 72,000
Output - Btuh 28,000 42,000 55,000 70,000
Temperature rise range - °F 20 - 50 25 - 55 30 - 60 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
1.7 / 4.5 1.7 / 4.5 1.7 / 4.5 1.7 / 4.5
High static - in. w.g. 0.5 0.5 0.5 0.5
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nom. diameter x width - in. 10 x 8 11-1/2 x 10 10 x 10 11 x 11
Motor Type DC Brushless DC Brushless DC Brushless DC Brushless
Motor output - hp 1/2 3/4 3/4 1
Tons of add-on cooling 1.5 - 3 2 - 4 2 - 4 3 - 5
Air Volume Range - cfm 485 - 1395 520 - 1770 760 - 1765 1045 - 2285
Electrical
Data
Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 6.8 8.4 8.4 10.9
Maximum overcurrent protection 15 15 15 15
Shipping Data lbs. - 1 package 134 145 163 175
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Eciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.