SPECIFICATIONS
Gas
Heating
Performance
ModelNo. G61MPV
−36B−045
G61MPV
−36B−070
G61MPV
−36B−071
G61MPV
−36C−090
High Fire
Input− Btuh
44,000 66,000 66,000 88,000
Output− Btuh 39,000 61,000 62,000 79,000
Temperature rise range − _F 20 − 50 45 − 75 45 − 75 70 − 100
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Low Fire
Input − Btuh 30,000 45,000 45,000 60,000
Output − Btuh 29,000 43,000 43,000 56,000
Temperature rise range − _F 10 − 40 25 − 55 20 − 50 35 − 65
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
1.7 / 4.9 1.7 / 4.9 1.7 / 4.9 1.7 / 4.9
1
AFUE 94.1% 94.1% 95.0% 94.3%
Highstatic(CSA)− in.w.g. .80 .80 .80 .80
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 2 / 2
Condensate Drain Trap (PVC pipe) − i.d. 1/2 1/2 1/2 1/2
with field supplied (PVC coupling) − o.d. 3/4 3/4 3/4 3/4
hose with hose clamp − i.d. x o.d. 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1
GaspipesizeIPS 1/2 1/2 1/2 1/2
Indoor
Blower
Wheelnominaldiameter xwidth −in. 10 x 8 10 x 8 10 x 8 10 x 10
Motoroutput − hp 1/2 1/2 1/2 1/2
Tons(kW) ofadd−oncooling 2 − 3 2 − 3.5 2 − 3.5 2 − 3.5
Air volume range cfm
610 1420 625 1395 625 1395 600 1395
ShippingData lbs. − 1 package 128 151 151 170
Electricalcharacteristics 120 volts − 60 hertz − 1 phase (less than 12 amps)
NOTE − Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non−weatherized furnaces.
Gas
Heating
Performance
ModelNo. G61MPV
−60C−090
G61MPV
−60C−091
G61MPV
−60C−110
G61MPV
−60C−111
G61MPV
−60D−135
High Fire
Input− Btuh 88,000 88,000 110,000 110,000 132,000
Output− Btuh 81,000 84,000 99,000 103,000 122,000
Temperature rise range − _F 40 − 70 40 − 70 50 − 80 50 − 80 65 − 95
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Low Fire
Input− Btuh 60,000 60,000 75,000 75,000 90,000
Output− Btuh 57,000 58,000 72,000 72,000 87,000
Temperature rise range − _F 20 − 50 20 − 50 30 − 60 25 − 55 40 − 70
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
1.7 / 4.9 1.7 / 4.9 1.7 / 4.9 1.7 / 4.9 1.7 / 4.9
1
AFUE 94.6% 95.0% 94.3% 95.0% 94.6%
Highstatic(CSA)− in.w.g. .80 .80 .80 .80 .80
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 2 / 2 3 / 3
Condensate Drain Trap (PVC pipe) − i.d. 1/2 1/2 1/2 1/2 1/2
with field supplied (PVC coupling) − o.d. 3/4 3/4 3/4 3/4 3/4
hose with hose clamp − i.d. x o.d. 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1
GaspipesizeIPS 1/2 1/2 1/2 1/2 1/2
Indoor
Blower
Wheelnominaldiameter xwidth −in. 11−1/2 x 10 11−1/2 x 10 11−1/2 x 10 11−1/2 x 10 11−1/2 x 10
Motoroutput − hp 1 1 1 1 1
Tons(kW) ofadd−oncooling 3.5 − 5 3.5 − 5 3.5 − 5 3.5 − 5 3.5 − 5
Air volume range cfm 895 2215 895 2215 740 2210 740 2210 915 2190
ShippingData lbs. − 1 package 180 180 188 188 207
Electricalcharacteristics 120 volts − 60 hertz − 1 phase (less than 12 amps)
NOTE − Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non−weatherized furnaces.