Page 3
OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA
B" Width Models C" Width Models D" Width Models
FILTER KITS
1
Air Filter and
Rack Kit
Horizontal (end) Size of filter − in. 87L96 − 18 x 25 x 1 87L97 − 20 x 25 x 1 87L98 − 25 x 25 x 1
Side Return
Single 44J22 44J22 44J22
Ten Pack 66K63 66K63 66K63
Size of filter − in. 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1
EZ Filter Base
Catalog No. − Ship. Wt. − lbs. 73P56 − 7 73P57 − 8 73P58 − 10
Size of field provided filter − in. 16 x 25 x 1 20 x 25 x 1 24 x 24 x 1
CABINET ACCESSORIES
Down−Flow Additive Base 11M60 11M61 11M62
Horizontal Support Frame Kit 56J18 56J18 56J18
Return Air Base 98M60 98M58 98M59
CONDENSATE DRAIN KITS
Condensate Drain Heat Cable
6 ft. 26K68 26K68 26K68
24 ft. 26K69 26K69 26K69
50 ft. 26K70 26K70 26K70
Heat Cable Tape
Fiberglass − 1/2 in. x 66 ft. 39G04 39G04 39G04
Aluminum foil − 2 in. x 60 ft. 39G03 39G03 39G03
Condensate Trap Alternate Location Kit − Up−Flow Only 76M20 76M20 76M20
CONTROLS
SignatureStat Home Comfort Control 81M27 81M27 81M27
TERMINATION KITS − See Installation Instructions for specific venting information.
2
Termination
Kits
Direct Vent
Applications
Only
Concentric
2 in. 71M80 69M29 − − −
3 in. − − − 60L46 60L46
Wall − Close Couple
2 in. 22G44 − − − − − −
3 in. 44J40 44J40 44J40
Close Couple WTK 2 in. 30G28 − − − − − −
3 in. 81J20 81J20 81J20
2
Termination
Kits − Direct or
Non−Direct Vent
Roof 2 in. 15F75 15F75
−
−
−
Wall − Wall Ring Kit 2 in. 15F74 15F74
3
15F74
2
Roof Termination Flashing Kit − Direct or Non−Direct
Vent − Contains two flashings.
44J41 44J41 44J41
1
Cleanable polyurethane frame type filter.
2
Kits contain enough parts for two, non−direct vent installations.
3
Non−direct vent only.
GAS HEAT ACCESSORIES
Input
High Altitude
Orifice Kit
Natural Gas
Only
High Altitude Pressure Switch Kit
ORDER TWO EACH
LPG/Propane Kit
LPG/Propane to
Natural Gas Kit
7501−10,000 ft. 2001−4500 ft. 4501−7500 ft. 7501−10,000 ft. 0−7500 ft. 7501−10,000 ft. 0−7500 ft.
1
7501−10,000 ft.
−045 59M17 − − − − − − − − − 59M13 59M14 59M87 59M87
−070 59M17 − − − − − − 56M23 59M13 59M14 59M87 59M87
−071 59M17 75M22 75M22 56M21 59M13 59M14 59M87 59M87
−090 59M17 − − − 75M22 56M21 59M13 59M14 59M87 59M87
−090
(036C−9
and
later
models)
59M17 − − − 24W51 24W49 59M13 59M14 59M87 59M87
−091 47M82 26W85 26W85 26W86 59M13 59M14 59M87 59M87
−110 59M17 − − − 56M23 75M22 59M13 59M14 59M87 59M87
−111 47M82 56M22 56M22 56M23 59M13 59M14 59M87 59M87
−135 59M17 − − − 56M93 56M93 59M13 59M14 59M87 59M87
1
High Altitude Orifice Kit is required and must be ordered separately for applications from 7501 to 10,000 ft.