14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS • MERIT PLUS
®
DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS
Note: Convert inches into metric equivalent
measurement, as follows:
Millimeters (mm) = Inches x 25.4
Centimeters (cm) = Inches x 2.54
Meters (M) = Inches x .0254
SV4.5FA or
SV4.5FB Flashing
AND SV4.5SC
Storm Collar
SV4.5VF
Firestop/Spacer*
1 in (25.4 mm)
Minimum
Clearance to
Combustibles
SV4.5CGV-1
Termination
SV4.5L6/12/24/36/48
Vent Sections
*When using Secure Flex,
use Firestop/Spacer
SF4.5VF.
Max. 40 ft
(12.2 m)
lanimoN
htgneLnoitceS
)sehcni(
621426384
T
O
T
A
L
Q
T
Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgie
HsnoitceStneVforebmuN
sehcnitf
5.4573.0100001
957.0200002
5.01578.0010001
5152.1110002
5.91526.12100
0
3
1257.1020002
5.22578.1001001
5.52521.2120003
5.13526.2030003
5.43578.2000101
5.7
3521.3111003
5.34526.3021003
5457.3002002
5.64578.3000011
5.94521.4102003
1552.4100012
5.55526.4012003
7557.4001102
6652.5022004
5.76526.5003003
9657.5000202
276103004
5.37521.6100203
5.97526.6010203
1857.6000112
095.7021014
5.195
26.7002013
3957.7000022
698101204
5.79521.8100023
2015.8200024
5.301526.8000303
8019100304
4115.9020024
71157.9105006
5.811578.9110305
6215.01001304
5.031578.01101305
53152.11006006
8315.11000404
5.931526.11000033
5.24157
8.11100405
noitceSlanimoN
)sehcni(htgneL
621426384
T
O
T
A
L
Q
T
Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgie
HsnoitceStneVforebmuN
sehcnitf
44121100034
0515.21010034
5.451578.21110035
5.061573.31020035
5.271573.41000505
77157.41100506
38152.51010506
6815.51000044
5.091578.51100045
5.69
1573.61010045
5.502521.71011507
70252.71000606
5.112526.71100607
5.712521.81010607
5.922521.91001607
5.232573.91000055
73257.91100056
5.142521.02000707
6425.02100708
25212010708
46222001708
67232000808
97252.32000066
5.082573.32100809
5.382526.32100067
5.982521.42010067
5.103521.52001067
5.013578.52000909
5135.621009001
5.523521.72000077
0335.72100078
63382010078
54357.8200001001
5.943521.9210001011
27313000088
5.673573.13100089
5.973526.1300011011
5.814578.43000099
32452.531000901
56457.8300000101
Model Effective Length
SV4.5L6 4 1/2 in.
SV4.5L12 10 1/2 in.
SV4.5L24 22 1/2 in.
SV4.5L36 34 1/2 in.
SV4.5L48 46 1/2 in.
Table 8: Effective Vent Length
Figure 19
Table 7: Vent Section Length
VERTICAL TERMINATION SYSTEMS (ROOF)
See Figure 19 and Figures 27 through
29 on Page 17 and their associated
Vertical Vent Tables, which illustrate the
various vertical venting confi gurations that
are possible for use with these appliances.
Secure Vent
®
pipe applications are shown in
these Figures; Secure Flex
®
pipe may also be
used. A Vertical Vent Table summarizes each
system’s minimum and maximum vertical
and horizontal length values that can be used
to design and install the vent components in
a variety of applications.
Both these vertical vent systems terminate
through the roof. The minimum vent height
above the roof and/or adjacent walls is
specifi ed in ANSI Z223.1-2009 (In Canada,
the current CAN/CSA-B149.1 installation
code) by major building codes. Always
consult your local codes for specifi c
requirements. A general guide to follow is the
Gas Vent Rule (refer to Figure 5 on Page 6).
Vertical (Straight) Installation
(Figure 19)
Determine the number of straight vent
sections required. 4 1/2 in. (114 mm),
10 1/2 in. (267 mm), 22 1/2 in. (572 mm),
34 1/2 in. (876 mm) and 46 1/2 in. (1181
mm) net section lengths are available (see
Tables on this page and Pages 36 and 37—
Vent Sections). Plan the vent lengths so that
a joint does not occur at the intersection
of ceiling or roof joists. Refer to the Vent
Section Length Chart.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MPD Series and is the answer not in the manual?

Lennox MPD Series Specifications

General IconGeneral
BrandLennox
ModelMPD Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals