TS − 3 to 5 Ton R−410A Air Conditioners / Page 10
ARI RATINGS
1
ARI Standard 210/240 Ratings
Ei
Cooling Capacity Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh SEER EER
Total
Unit
Watts
D
ev
i
ce
TSA036S4 3 TON
Up-Flow Indoor Coils Up−Flow Coils
33,800 13.00 10.90 3100
3,
5
CX34−38B−6F Factory TXV
34,600 13.00 11.00 3145
3
CX34−50/60C−6F
2
37L51
34,800 13.00 11.00 3165
3
CX34−43B−6F
2
37L51
Up-Flow Indoor Coils + Furnace Up−Flow Coils + Furnace
34,400 13.50 11.50 2990 CX34−36C−6F
4
G61MPV−36C−090 Factory TXV
34,400 13.50 11.50 2990 CX34−36C−6F
4
G71MPP−36C−090 Factory TXV
34,800 14.00 11.60 3000 CX34−38B−6F
4
G61MPV−36B−070 Factory TXV
34,800 14.00 11.60 3000 CX34−38B−6F
4
G71MPP−36B−070 Factory TXV
35,000 13.50 11.60 3015 CX34−38A−6F
4
G60UHV−36A−070 Factory TXV
35,000 13.50 11.60 3015 CX34−38B−6F
4
G61MPV−36B−045 Factory TXV
35,200 14.00 11.60 3035 CX34−38B−6F
4
G60UHV−36B−090 Factory TXV
35,200 14.00 11.60 3035 CX34−43B−6F
4
G61MPV−36B−045
2
37L51
35,200 14.00 11.60 3035 CX34−43B−6F
4
G61MPV−36B−070
2
37L51
35,200 14.00 11.60 3035 CX34−43B−6F
4
G71MPP−36B−070
2
37L51
35,600 14.00 11.60 3070 CX34−43B−6F
4
G61MPV−36B−071
2
37L51
35,600 14.00 11.60 3070 CX34−50/60C−6F
4
G61MPV−60C−090
2
37L51
35,600 14.00 11.60 3070 CX34−50/60C−6F
4
G71MPP−60C−090
2
37L51
35,600 14.00 12.00 2965 CX34−43B−6F
4
G60UHV−36B−090
2
37L51
35,600 14.00 12.00 2965 CX34−50/60C−6F
4
G60UHV−60C−110
2
37L51
36,400 14.00 11.60 3140 CX34−50/60C−6F
4
G61MPV−60C−091
2
37L51
36,400 14.00 11.60 3140 CX34−50/60C−6F
4
G61MPV−60C−111
2
37L51
Down-Flow Indoor Coils Down−Flow Coils
34,000 13.00 11.00 3090
3
CR33−48B−F
2
37L51
Down-Flow Indoor Coils + Furnace Down−Flow Coils + Furnace
33,400 13.50 11.00 3035 CR33−48B−F
4
G61MPV−36B−070
2
37L51
33,400 13.50 11.00 3035 CR33−48B−F
4
G71MPP−36B−070
2
37L51
33,600 13.00 11.00 3055 CR33−48B−F
4
G61MPV−36B−045
2
37L51
33,800 14.00 11.60 2915 CR33−48B−F
4
G60DFV−36B−090
2
37L51
34,200 13.50 11.00 3110 CR33−48B−F
4
G61MPV−36B−071
2
37L51
34,800 13.50 11.50 3025 CR33−30/36C−F
4
G61MPV−36C−090
2
37L51
34,800 13.50 11.50 3025 CR33−30/36C−F
4
G71MPP−36C−090
2
37L51
Horizontal Indoor Coils Horizontal Coils
34,600 13.00 11.00 3145
3
CH33−44/48B−2F
2
37L51
34,800 13.00 11.00 3165
3
CH33−48C−2F
2
37L51
36,200 13.50 11.00 3290
3
CH33−43B−2F
2
37L51
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95_F outdoor air temperature, 80_F db/67_F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox TSA036S4 and is the answer not in the manual?

Lennox TSA036S4 Specifications

General IconGeneral
BrandLennox
ModelTSA036S4
CategoryAir Conditioner
LanguageEnglish

Related product manuals