2
Model Number Identi cation
Safety Requirements
ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD.
Do not touch the unit or the controller if your hands are wet.
Do not operate appliances with an open ame near the unit.
Do not replace a fuse with a fuse of a different rating. Do not use a jumper wire to replace a fuse. Do not insert
your hands, tools or any other item into the air intake or air outlet at either the indoor or outdoor unit.
Do not allow children to operate the system.
WARNING
!
V P A 036 H 4 M - 2 P
Brand/Family
V = Variable Refrigerant Flow (VRF)
Unit Type
P = Heat Pump Outdoor Unit
Major Design Sequence
A = 1st Generation
Voltage
P = 208/230V-1 phase-60hz
Cooling Ef ciency
H = High Ef ciency
Minor Design Sequence
1 = 1st Revision
2 = 2nd Revision
3 = 3rd Revision
Refrigerant Type
4 = R-410A
Refrigerant Circuits
M = Multiple Circuits
Nominal Cooling Capacity - Tons
036 = 3 Tons
048 = 4 Tons
060 = 5 Tons
System Piping
CAUTION
VRF system piping is customized for each installation.
The Lennox VRF Selection Software (LVSS) piping
report is an engineered design that must be followed.
The piping diagram or diagrams included within the LVSS
report have been prepared based on the information
provided to the Lennox VRF applications department.
When the indicated lengths change from the gures
stated within the report, it is imperative that prior to the
commencement of the refrigerant pipe work installation,
Lennox VRF applications department are informed of
these proposed changes.
Upon receipt of this new information the Lennox VRF
applications department will con rm any changes that
may be applicable to this installation. If changes are
required, a new piping diagram will be produced and will
supersede all other previously provided documents.
Failure to provide this information regarding changes
to the original design may lead to insuf cient capacity,
equipment failure, warranty being made void and the
refusal to commission the system.
CAUTION
NOTE - Lennox VRF and Lennox Mini-Split products are similar in appearance to each other. Refer to the unit’s model
number to determine if the unit is a VRF (V) or Mini-Split (M) unit. It is not possible to mix the two types of equipment
on any system.