SPECIFICATIONS
General
Model No. XC16−024 XC16−036 XC16−048 XC16−060
Data
Nominal Tonnage 2
3 4 5
Connections
Liquid line (o.d.) − in. 3/8 3/8 3/8 3/8
(sweat)
Suction line (o.d.) − in. 3/4
7/8 7/8 1−1/8
Refrigerant
1
R−410A charge furnished 7 lbs. 5 oz. 8 lbs. 9 oz. 11 lbs. 4 oz. 14 lbs. 2 oz.
Outdoor
Net face area − sq. ft. Outer coil 13.22 16.33 21.00 24.93
Coil
Inner coil 12.65
15.76 20.27 24.14
Tube diameter − in. 5/16 5/16 5/16 5/16
No. of rows 2 2 2 2
Fins per inch 22 22 22 22
Outdoor
Diameter − in. 18 22 22 26
Fan
No. of blades 3
4 4 3
Motor hp 1/10 1/6 1/4 1/3
Cfm 2320 3060 3955 4380
Rpm 1130 845 835 850
Watts 165 215 320 280
Shipping Data − lbs. 1 pkg. 208 238 268 323
ELECTRICAL DATA
Line voltage data − 60hz
4
230V−1ph
4
230V−1ph
4
230V−1ph
4
230V−1ph
3
Maximum overcurrent protection (amps) 20 35 45 55
2
Minimum circuit ampacity 13.6 22.0 28.2 33.9
Compressor Rated load amps 10.3 16.7 21.2 25.6
Locked rotor amps 52 82 96 118
Power factor 0.98 0.99 0.99 0.99
Outdoor Fan
Full load amps 0.7 1.1 1.7 1.8
Motor
Locked Rotor amps 2
2.1 3.1 2.9
OPTIONAL ACCESSORIES − must be ordered extra
Compressor Hard Start Kit 10J42
81J69
Compressor Low Ambient Cut−Off 45F08
Compressor Time−Off Control 47J27
Freezestat 3/8 in. tubing 93G35
5/8 in. tubing 50A93
Indoor Blower Relay 40K58
Low Ambient Kit 68M04
SignatureStatt Home Comfort Control 81M27
Refrigerant
Line Sets
L15−41−20
L15−41−30
L15−65−40
L15−65−50
L15−65−30
L15−65−40
L15−65−50
Field Fabricate
Time Delay Relay 58M81
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
HACR type breaker or fuse.
4
Hard start kit is required in applications where the supply voltage is less than 230V.